Widespread Choroidal Insufficiency in Primary Open-Angle Glaucoma
The DOI matches its Crossref record.
Abstract
PURPOSE: The purpose of this study was to investigate choroidal perfusion in glaucoma, using histological and angiographic techniques. METHODS: We examined the choroidal vasculature in clinicopathological slides from 25 cases of primary open-angle glaucoma, five cases of optic atrophy, and 18 normal eyes. We measured choroidal thickness at fixed distances from the disk margin with light microscopy. Using a quantitative computer image analysis system, we established the depth of all vessels and the best fitting diameter and width-to-length ratio for each vessel in three pairs of eyes. Separate statistical analyses were done on the parapapillary area and the whole choroid. We compared standard fluorescein angiographic measures to peak choroidal filling time in a further 78 glaucoma and 84 normal eyes. RESULTS: Choroids were significantly (approximately 50 microns) thinner in glaucoma than in normal or optic atrophy irrespective of fundal position. Vessel frequency and mean diameter, relative to normal, showed greatest decrease near the choriocapillaris. Peak choroidal filling was the only fluorescein angiographic measure that was significantly delayed in glaucoma irrespective of age. CONCLUSIONS: Reduced choroidal thickness in primary open-angle glaucoma is primarily due to loss of the innermost choroidal vessels. Overall size decreases without significant flattening. These changes are not seen with optic atrophy alone and may be correlated with the delayed choroidal perfusion seen in fluorescein angiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Optical coherence tomography: Imaging of the choroid and beyond
Mrejen, S., & Spaide, R. F. (2013) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.12.001 · Cited by 477
Wang, X., Jiang, C., Ko, T., Kong, X., Yu, X., Min, W., Shi, G., & Sun, X. (2015) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-015-3095-y · Cited by 350
Risk Factors and Open-angle Glaucoma: Classification and Application
Boland, M. V., & Quigley, H. A. (2007) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31806540a1 · Cited by 235
“Choroidal thickness has been reported to be thinner in OAG than in control eyes in histologic studies of postmortem tissue.(57) Again, it is logical that the finding may be an effect of chronically higher IOP, rather than a causative feature.”
BackgroundVascular Aspects in the Pathophysiology of Glaucomatous Optic Neuropathy
Chung, H. S., Harris, A., Evans, D. W., Kagemann, L., Garzozi, H. J., & Martin, B. (1999) · Survey of Ophthalmology · doi:10.1016/s0039-6257(99)00050-8 · Cited by 190
Metadata
- Authors
- Yin, Z. Q., Vaegan, Millar, T. J., Beaumont, P., & Sarks, S.
- Venue
- Journal of Glaucoma
- Published
- 1997-02
- Volume
- 6
- Issue
- 1
- Pages
- 23???32
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2035816592
- Cited by
- 208
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Widespread Choroidal Insufficiency in Primary Open-Angle Glaucoma. https://app.cochat.ai/papers/10.1097/00061198-199702000-00006
- The paper
- Yin, Z. Q., Vaegan, Millar, T. J., Beaumont, P., & Sarks, S. (1997). Widespread Choroidal Insufficiency in Primary Open-Angle Glaucoma. Journal of Glaucoma. https://doi.org/10.1097/00061198-199702000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.