The DOI matches its Crossref record.
Clinical application of the PFA-100®
Abstract
The PFA-100 (platelet function analyzer) is a relatively new tool for the investigation of primary hemostasis. Recent studies have shown its utility as a screening tool for investigating possible von Willebrand disorder (VWD) and various platelet disorders. More recently, the PFA-100 has been shown to be valuable in monitoring desmopressin acetate (DDAVP) therapy in both VWD and platelet disorders. The PFA-100 has also been evaluated in many other studies for its utility in assessing drug effects, for potential monitoring of antiplatelet medication (including aspirin), or for evaluation of overall primary hemostasis in various clinical disorders or during surgical procedures. This article reviews current findings and highlights the benefits and limitations of the clinical utility of the PFA-100. Ultimately, the greatest strengths of the PFA-100 are its simplicity of use and excellent sensitivity to particular hemostatic disturbances such as VWD, platelet disorders, and platelet-affecting medication. However, because it is thus a global test system, this also creates a significant limitation because the PFA-100 is not specific for, nor predictive of, any particular disorder. However, used appropriately, the PFA-100 can be considered a worthwhile addition to any hemostasis laboratory involved in the diagnosis or therapeutic monitoring of bleeding disorders and potentially of antiplatelet medication. This review should be valuable to both hemostasis scientists and clinical specialists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Platelet function tests: a comparative review
Paniccia, R., Priora, R., Alessandrello Liotta, A., & Abbate, R. (2015) · Vascular Health and Risk Management · doi:10.2147/vhrm.s44469 · Cited by 505
HAYWARD, C. P. M., HARRISON, P., CATTANEO, M., ORTEL, T. L., & RAO, A. K. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01771.x · Cited by 404
Harrison, P. (2005) · Blood Reviews · doi:10.1016/j.blre.2004.05.002 · Cited by 352
Angiolillo, D. J., Bernardo, E., Ramírez, C., Costa, M. A., Sabaté, M., Jimenez-Quevedo, P., Hernández, R., Moreno, R., Escaned, J., Alfonso, F., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.038 · Cited by 310
Platelet function predicts myocardial damage in patients with acute myocardial infarction
Frossard, M., Fuchs, I., Leitner, J. M., Hsieh, K., Vlcek, M., Losert, H., Domanovits, H., Schreiber, W., Laggner, A. N., & Jilma, B. (2004) · Circulation · doi:10.1161/01.cir.0000141575.92958.9c · Cited by 254
Metadata
- Authors
- Favaloro, E. J.
- Venue
- Current Opinion in Hematology
- Published
- 2002-09
- Volume
- 9
- Issue
- 5
- Pages
- 407-415
- ISSN
- 1065-6251 (ISSN-L)
- OpenAlex
- W1982535916
- Cited by
- 178
- References
- 0
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical application of the PFA-100®. https://app.cochat.ai/papers/10.1097/00062752-200209000-00004
- The paper
- Favaloro, E. J. (2002). Clinical application of the PFA-100®. Current Opinion in Hematology. https://doi.org/10.1097/00062752-200209000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.