CoChat

Isotopic investigation of nitric oxide metabolism in disease

Luiking, Yvette C., Deutz, Nicolaas E.P. · 2003 · Current Opinion in Clinical Nutrition and Metabolic Care
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE OF REVIEW: Nitric oxide is an important mediator of both physiological and pathophysiological processes. Nitric oxide is produced during direct conversion of arginine to citrulline. Nitric oxide is rapidly metabolized, mainly to nitrite/nitrate, and finally excreted as urinary nitrate. For that reason, plasma and urinary nitrite/nitrate have been measured frequently as indicators of nitric oxide production, but it is becoming clear that these methods only give qualitative data. More recently, stable isotope methods have been introduced for quantitative measurement of nitric oxide production. This review aims at summarizing and evaluating these isotopic investigations of nitric oxide metabolism in disease. RECENT FINDINGS: Different stable isotope methods are used to measure whole body nitric oxide production in vivo. These methods are all based on infusion of guanidino-labeled L-arginine and subsequent measurement of labeled products (e.g. nitrite/nitrate or citrulline). Nitric oxide synthesis in healthy individuals is found to be in the range of 0.2-1.0 micromol kg h, only 0.5-1% of arginine production. In diseased states, nitric oxide synthesis was found to be either decreased or increased. Increased nitric oxide synthesis was observed in gastroenteritis patients and in some animal models of sepsis. In patients with renal failure, however, both increased and decreased nitric oxide production have been reported. Nitric oxide production was not changed in familial hypercholesterolemia patients and after typhoid vaccination. SUMMARY: Using stable isotopes to measure whole body nitric oxide production in vivo is the most accurate method to study quantitative changes in the nitric oxide production rate. This technique is easy to perform in both healthy and diseased individuals, requiring infusion of stable isotopes for only a few hours and blood sampling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00075197-200301000-00015

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 45

Metadata

Authors
Luiking, Y. C., & Deutz, N. E. P.
Venue
Current Opinion in Clinical Nutrition and Metabolic Care
Published
2003-01
Volume
6
Issue
1
Pages
103-108
ISSN
1363-1950 (ISSN-L)
OpenAlex
W2325414298
Cited by
45
References
2
FWCI
2.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isotopic investigation of nitric oxide metabolism in disease. https://app.cochat.ai/papers/10.1097/00075197-200301000-00015
The paper
Luiking, Y. C., & Deutz, N. E. P. (2003). Isotopic investigation of nitric oxide metabolism in disease. Current Opinion in Clinical Nutrition and Metabolic Care. https://doi.org/10.1097/00075197-200301000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.