The Relative Efficiency of Altering Pulse Frequency or Train Duration When Determining Seizure Threshold
The DOI matches its Crossref record.
Abstract
In 12 depressed inpatients referred for bilateral electroconvulsive therapy (ECT), each patient was titrated at the first treatment session by using an ascending method-of-limits procedure with a step-wise increase in pulse frequency (frequency titration) or train duration (duration titration). At the second treatment session, seizure threshold was redetermined by using the method (frequency or duration titration) not used at the first treatment. Frequency or duration was maintained at the lowest level when the other parameter was titrated. Seizure threshold was significantly lower with duration titration (mean, 90 mC; SD, 27.3) than frequency titration (mean, 114 mC; SD, 35.6; p = 0.03). On average, patients in the duration-titration group required 1.2 (SD, 0.6) subconvulsive stimulations before a seizure was elicited, and patients in the frequency-titration group required 1.7 (SD, 0.9) subconvulsive stimulations before a seizure was elicited, a nonsignificant difference. These findings suggest that to elicit a seizure during ECT, increasing train duration may be slightly more efficient than increasing frequency. Basic and other clinical research findings indicate that increasing pulse width may be an inefficient way to elicit a seizure. Therefore the following sequence in the determination of seizure threshold is worth considering when using dose-titration or related techniques: the train duration should be increased first before increasing pulse frequency, and the decision to increase pulse width should be reserved for patients who do not seize at the maximal duration and frequency settings. Further empiric research is needed to establish the utility of this approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
Self-citationUpdate on Magnetic Seizure Therapy: A Novel Form of Convulsive Therapy
Lisanby, S. H. (2002) · The Journal of ECT · doi:10.1097/00124509-200212000-00003 · Cited by 107
“Studies suggest that stimulus configurations using a longer train duration are more efficient in inducing seizure than those using a higher pulse frequency or wider pulse width (19,20).”
BackgroundSelf-citationRadman, T., & Lisanby, S. H. (2017) · International Review of Psychiatry · doi:10.1080/09540261.2017.1304898 · Cited by 14
“…the intended dosage relative to ST, the duration and frequency of the pulse train are increased above the minimum necessary to induce a seizure (Devanand et al., 1998; Swartz, 2000); however, the rationale behind why increasing the number of delivered pulses would increase antidepressant…”
BackgroundSelf-citationBergsholm, P., & Bjølseth, T. M. (2022) · Nordic Journal of Psychiatry · doi:10.1080/08039488.2021.1946590 · Cited by 8
“The previously established Scandinavian time-titration dosing may be the simplest and most efficacious stimulation method for individualized dosing [3,6].”
Metadata
- Authors
- Devanand, D. P., Lisanby, S. H., Nobler, M. S., & Sackeim, H. A.
- Venue
- The Journal of ECT
- Published
- 1998-12
- Volume
- 14
- Issue
- 4
- Pages
- 227???235
- ISSN
- 1095-0680 (ISSN-L)
- OpenAlex
- W2050788911
- Cited by
- 47
- References
- 0
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Relative Efficiency of Altering Pulse Frequency or Train Duration When Determining Seizure Threshold. https://app.cochat.ai/papers/10.1097/00124509-199812000-00002
- The paper
- Devanand, D. P., Lisanby, S. H., Nobler, M. S., & Sackeim, H. A. (1998). The Relative Efficiency of Altering Pulse Frequency or Train Duration When Determining Seizure Threshold. The Journal of ECT. https://doi.org/10.1097/00124509-199812000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.