OBJECTIVES: In the European Project on Genes in Hypertension (EPOGH) standardized epidemiological methods were used to determine complex phenotypes consisting of blood pressure (BP) in combination with other traits. In this report, we present the quality control of one of the BP phenotypes. METHODS: In seven European countries eight different research groups recruited random samples of nuclear families. Trained observers measured the BP five times consecutively with the participants in the seated position at each of two separate home visits, 1 to 3 weeks apart, according to the guidelines of the British Hypertension Society. Quality assurance and quality control of this BP phenotype were implemented according to detailed instructions defined in the protocol of the EPOGH study. RESULTS: On 31 August 2001, BP measurements of 2476 subjects were available for analysis. Fewer BP readings than the five planned per visit occurred in one of the eight centres, but only in 0.4% of the home visits. Across centres the relative frequency of identical consecutive readings for systolic or diastolic blood pressure varied from 0 to 6%. The occurrence of odd readings ranged from 0 to 0.1%. Of the 49,488 systolic and diastolic BP readings, 24.0% ended on a zero (expected 20%). In most EPOGH centres there was a progressive decline in the BP from the first to the second home visit. Overall, these decreases averaged 2.36 mmHg [95% confidence interval (CI): 1.98-2.74, P < 0.001] for systolic BP and 1.74 mmHg (95% CI: 1.46-2.02, P < 0.001) for diastolic BP. CONCLUSIONS: Quality assurance and control should be planned at the design stage of a project involving BP measurement and implemented from its very beginnings until the end. The procedures of quality assurance set up in the EPOGH study for the BP measurements resulted in a well-defined BP phenotype, which was consistent across centres.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200208000-00003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 104

Metadata

Authors
Kuznetsova, T., Staessen, J. A., Kawecka-Jaszcz, K., Babeanu, S., Casiglia, E., Filipovsky, J., Nachev, C., Nikitin, Y., Peleskã, J., & OʼBrien, E.
Venue
Blood Pressure Monitoring
Published
2002-08
Volume
7
Issue
4
Pages
215-224
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2150041088
Cited by
104
References
2
FWCI
3.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality control of the blood pressure phenotype in the European Project on Genes in Hypertension. https://app.cochat.ai/papers/10.1097/00126097-200208000-00003
The paper
Kuznetsova, T., Staessen, J. A., Kawecka-Jaszcz, K., Babeanu, S., Casiglia, E., Filipovsky, J., Nachev, C., Nikitin, Y., Peleskã, J., & OʼBrien, E. (2002). Quality control of the blood pressure phenotype in the European Project on Genes in Hypertension. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200208000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.