Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure
Abstract
OBJECTIVE: To evaluate three methods aimed at the reconstruction of brachial pressure from non-invasive finger arterial pressure measurements as implemented in the Finometer trade mark, (FMS, Finapres Measurement Systems, Arnhem, Netherlands), the successor to the Finapres trade mark (TNO Biomedical Instrumentation, Amsterdam, Netherlands). METHODS: Finger arterial pressure (FinAP) may differ from intra-brachial pressure (BAP). Pulse shape differences are removed by applying a generalized waveform filter. Pressure level differences are corrected by a generalized level correction equation using filtered systolic and diastolic levels and by level calibration, which uses an additional return-to-flow (RTF) systolic pressure measurement on the ipsilateral upper arm for an individual calibration of the reconstructed brachial pressure. VALIDATION: These methods were validated in 37 subjects, aged 41 to 83 years after a cardiac catheterization procedure. Intra-brachial and Finometer pressures were recorded simultaneously. Finometer pressures were compared after application of waveform filtering and level correction (flcAP), and after an additional RTF calibration (reBAP). RESULTS: Finger arterial systolic, diastolic and mean pressures for the group differed from BAP by -9.7 +/- 13.0, -11.6 +/- 8.0 and -16.3 +/- 7.9 mmHg (mean +/- SD) respectively. Similarly flcAP differed by -1.1 +/- 10.7, -0.2 +/- 6.8 and -1.5 +/- 6.6 mmHg and reBAP differed by 3.1 +/- 7.6, 4.0 +/- 5.6 and 2.7 +/- 4.7 mmHg. CONCLUSION: Reconstruction of BAP from FinAP as implemented in the Finometer reduces the pressure differences, with an individual RTF calibration to well within AAMI requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Collier, S. R., Kanaley, J. A., Carhart, R., Frechette, V, Tobin, M. M., Hall, A. K., Luckenbaugh, A. N., & Fernhall, B. (2008) · Journal of Human Hypertension · doi:10.1038/jhh.2008.36 · Cited by 303
Juraschek, S. P., Guallar, E., Appel, L. J., & Miller, E. R. (2012) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.027995 · Cited by 294
Metadata
- Authors
- Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W.
- Venue
- Blood Pressure Monitoring
- Published
- 2003-02
- Volume
- 8
- Issue
- 1
- Pages
- 27-30
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2023007390
- Cited by
- 219
- References
- 0
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. https://app.cochat.ai/papers/10.1097/00126097-200302000-00006
- The paper
- Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2003). Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200302000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.