Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure

Guelen, Ilja, Westerhof, Berend E., van der Sar, Gertrude L., van Montfrans, Gert A., Kiemeneij, Ferdinand, Wesseling, Karel H., Bos, Willem Jan W.·2003·Blood Pressure Monitoring

Abstract

OBJECTIVE: To evaluate three methods aimed at the reconstruction of brachial pressure from non-invasive finger arterial pressure measurements as implemented in the Finometer trade mark, (FMS, Finapres Measurement Systems, Arnhem, Netherlands), the successor to the Finapres trade mark (TNO Biomedical Instrumentation, Amsterdam, Netherlands). METHODS: Finger arterial pressure (FinAP) may differ from intra-brachial pressure (BAP). Pulse shape differences are removed by applying a generalized waveform filter. Pressure level differences are corrected by a generalized level correction equation using filtered systolic and diastolic levels and by level calibration, which uses an additional return-to-flow (RTF) systolic pressure measurement on the ipsilateral upper arm for an individual calibration of the reconstructed brachial pressure. VALIDATION: These methods were validated in 37 subjects, aged 41 to 83 years after a cardiac catheterization procedure. Intra-brachial and Finometer pressures were recorded simultaneously. Finometer pressures were compared after application of waveform filtering and level correction (flcAP), and after an additional RTF calibration (reBAP). RESULTS: Finger arterial systolic, diastolic and mean pressures for the group differed from BAP by -9.7 +/- 13.0, -11.6 +/- 8.0 and -16.3 +/- 7.9 mmHg (mean +/- SD) respectively. Similarly flcAP differed by -1.1 +/- 10.7, -0.2 +/- 6.8 and -1.5 +/- 6.6 mmHg and reBAP differed by 3.1 +/- 7.6, 4.0 +/- 5.6 and 2.7 +/- 4.7 mmHg. CONCLUSION: Reconstruction of BAP from FinAP as implemented in the Finometer reduces the pressure differences, with an individual RTF calibration to well within AAMI requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200302000-00006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W.
Venue
Blood Pressure Monitoring
Published
2003-02
Volume
8
Issue
1
Pages
27-30
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2023007390
Cited by
219
References
0
FWCI
4.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. https://app.cochat.ai/papers/10.1097/00126097-200302000-00006
The paper
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2003). Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200302000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.