Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 232

The DOI matches its Crossref record.

Quad Screen as a Predictor of Adverse Pregnancy Outcome

Dugoff, Lorraine, Hobbins, John C., Malone, Fergal D., Vidaver, John, Sullivan, Lisa, Canick, Jacob A., Lambert-Messerlian, Geralyn M., Porter, T Flint, Luthy, David A., Comstock, Christine H., Saade, George, Eddleman, Keith, Merkatz, Irwin R., Craigo, Sabrina D., Timor-Tritsch, Ilan E., Carr, Stephen R., Wolfe, Honor M., DʼAlton, Mary E. · 2005 · Obstetrics & Gynecology

Abstract

OBJECTIVE: To estimate the effect of second-trimester levels of maternal serum alpha-fetoprotein (AFP), human chorionic gonadotrophin (hCG), unconjugated estriol (uE3), and inhibin A (the quad screen) on obstetric complications by using a large, prospectively collected database (the FASTER database). METHODS: The FASTER trial was a multicenter study that evaluated first- and second-trimester screening programs for aneuploidy in women with singleton pregnancies. As part of this trial, patients had a quad screen drawn at 15-18 6/7 weeks. We analyzed the data to identify associations between the quad screen markers and preterm birth, intrauterine growth restriction, preeclampsia, and fetal loss. Our analysis was performed by evaluating the performance characteristics of quad screen markers individually and in combination. Crude and adjusted effects were estimated by multivariable logistic regression analysis. Patients with fetal anomalies were excluded from the analysis. RESULTS: We analyzed data from 33,145 pregnancies. We identified numerous associations between the markers and the adverse outcomes. There was a relatively low, but often significant, risk of having an adverse pregnancy complication if a patient had a single abnormal marker. However, the risk of having an adverse outcome increased significantly if a patient had 2 or more abnormal markers. The sensitivity and positive predictive values using combinations of markers is relatively low, although superior to using individual markers. CONCLUSION: These data suggest that components of the quad screen may prove useful in predicting adverse obstetric outcomes. We also showed that the total number and specific combinations of abnormal markers are most useful in predicting the risk of adverse perinatal outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.aog.0000172419.37410.eb

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Dugoff, L., Hobbins, J. C., Malone, F. D., Vidaver, J., Sullivan, L., Canick, J. A., Lambert-Messerlian, G. M., Porter, T. F., Luthy, D. A., Comstock, C. H., Saade, G., Eddleman, K., Merkatz, I. R., Craigo, S. D., Timor-Tritsch, I. E., Carr, S. R., Wolfe, H. M., & DʼAlton, M. E.
Venue
Obstetrics & Gynecology
Published
2005-08
Volume
106
Issue
2
Pages
260-267
ISSN
0029-7844 (ISSN-L)
OpenAlex
W2085538044
Cited by
232
References
0
FWCI
8.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quad Screen as a Predictor of Adverse Pregnancy Outcome. https://app.cochat.ai/papers/10.1097/01.aog.0000172419.37410.eb
The paper
Dugoff, L., Hobbins, J. C., Malone, F. D., Vidaver, J., Sullivan, L., Canick, J. A., Lambert-Messerlian, G. M., Porter, T. F., Luthy, D. A., Comstock, C. H., Saade, G., Eddleman, K., Merkatz, I. R., Craigo, S. D., Timor-Tritsch, I. E., Carr, S. R., Wolfe, H. M., & DʼAlton, M. E. (2005). Quad Screen as a Predictor of Adverse Pregnancy Outcome. Obstetrics & Gynecology. https://doi.org/10.1097/01.aog.0000172419.37410.eb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.