Umbilical Coiling Index in Normal and Complicated Pregnancies
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To estimate the relation between undercoiling and overcoiling of the umbilical cord and adverse pregnancy outcome. METHODS: Umbilical cords and hospital records of 885 patients were studied in a cross-sectional study design. The umbilical coiling index was determined as the number of complete coils divided by the length of the cord in centimeters, blinded for pregnancy outcome. Obstetric history and pregnancy outcome of each patient were obtained from hospital records, blinded for the umbilical coiling index. Odds ratios and their 95% confidence intervals were calculated to evaluate associations between undercoiling and overcoiling and adverse pregnancy outcome, using multiple logistic regression. RESULTS: Undercoiling (umbilical coiling index below the 10th percentile, using references values from uncomplicated pregnancies) was associated with fetal death (odds ratio [OR] 3.35, 95% confidence interval [CI] 1.48-7.63), spontaneous preterm delivery (OR 2.16, 95% CI 1.34-3.48), trisomies (OR 5.79, 95% CI 2.07-16.24), low Apgar score at 5 minutes (OR 3.14, 95% CI 1.47-6.70), velamentous cord insertion (OR 3.00, 95% CI 1.16-7.76), single umbilical artery (OR 3.68, 95% CI 1.26-10.79), and dextral coiling (OR 1.80, 95% CI 1.02-3.17). Overcoiling (umbilical coiling index above the 90th percentile) was associated with asphyxia (OR 4.16, 95% CI 1.30-13.36), umbilical arterial pH < 7.05 (OR 2.91, 95% CI 1.05-8.09), small for gestational age infants (OR 2.10, 95% CI 1.01-4.36), trisomies (OR 9.26, 95% CI 2.84-30.2), single umbilical artery (OR 8.25, 95% CI 2.60-26.12), and sinistral coiling (OR 4.30, 95% CI 1.52-12.2). CONCLUSION: Undercoiling and overcoiling of the umbilical cord are associated with increased risk for adverse perinatal outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Khong, T. Y., Mooney, E. E., Ariel, I., Balmus, N. C. M., Boyd, T. K., Brundler, M.-A., Derricott, H., Evans, M. J., Faye-Petersen, O. M., Gillan, J. E., et al. (2016) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2015-0225-cc · Cited by 1,737
Self-citationRoescher, A. M., Timmer, A., Erwich, J. J. H. M., & Bos, A. F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089419 · Cited by 180
Pathak, S., Hook, E., Hackett, G., Murdoch, E., Sebire, N. J., Jessop, F., & Lees, C. (2010) · Placenta · doi:10.1016/j.placenta.2010.08.004 · Cited by 72
Pathophysiological significance of abnormal umbilical cord coiling index
Sebire, N. J. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5180 · Cited by 40
Ultrasound screening of umbilical cord abnormalities and delivery management
Hasegawa, J. (2018) · Placenta · doi:10.1016/j.placenta.2017.12.003 · Cited by 40
Metadata
- Authors
- de Laat, M. W. M., Franx, A., Bots, M. L., Visser, G. H. A., & Nikkels, P. G. J.
- Venue
- Obstetrics & Gynecology
- Published
- 2006-05
- Volume
- 107
- Issue
- 5
- Pages
- 1049-1055
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1980096959
- Cited by
- 125
- References
- 0
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Umbilical Coiling Index in Normal and Complicated Pregnancies. https://app.cochat.ai/papers/10.1097/01.aog.0000209197.84185.15
- The paper
- de Laat, M. W. M., Franx, A., Bots, M. L., Visser, G. H. A., & Nikkels, P. G. J. (2006). Umbilical Coiling Index in Normal and Complicated Pregnancies. Obstetrics & Gynecology. https://doi.org/10.1097/01.aog.0000209197.84185.15
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.