Regular Monitoring of Access Flow Compared with Monitoring of Venous Pressure Fails to Improve Graft Survival
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Regular vascular access blood flow (Qa) surveillance is recommended to detect graft stenosis; however, there is little evidence that monitoring and correcting with angioplasty improves graft survival. This blinded, randomized, controlled trial of 112 patients studied time to graft thrombosis and graft loss, comparing monthly Qa plus standard surveillance (dynamic venous pressure and physical examination) (treatment group) to standard surveillance alone (control group). Only the treatment group was referred for angiogram if Qa <650 ml/min or a 20% decrease in Qa from baseline. Percutaneous angioplasty was performed for stenosis >50%. The rate of graft thrombosis per patient-year at risk was 0.41 and 0.51 in the control and treatment groups, respectively. Fifty-one interventions (0.93/patient-years at risk) were performed in the treatment group versus 31 interventions (0.61/patient-years at risk) in the control group. There was no difference in time to graft loss (P = 0.890). In a multivariate analysis, aspirin (ASA) therapy at baseline was associated with an 84% reduction in risk of graft thrombosis (odds ratio [OR], 0.14; P = 0.002). Higher baseline Qa (OR, 0.84; P = 0.05) and longer interval since graft insertion (OR, 0.97; P = 0.07) were associated with a decrease in graft thrombosis. Results reveal that graft surveillance that uses Qa increases the detection of stenosis, compared with standard surveillance; however, intervention with angioplasty does not improve the time to graft thrombosis or time to graft loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Practice Guidelines for Vascular Access
(2006) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2006.04.040 · Cited by 1,593
Hemodialysis vascular access morbidity.
Feldman, H. I., Kobrin, S., & Wasserstein, A. (1996) · Journal of the American Society of Nephrology · doi:10.1681/asn.v74523 · Cited by 667
Vascular access for hemodialysis
Schwab, S. J. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00409.x · Cited by 564
Canadian Hemodialysis Morbidity Study
Churchill, D. N., Taylor, D. W., Cook, R. J., LaPlante, P., Barre, P., Cartier, P., Fay, W. P., Goldstein, M. B., Jindal, K., Mandin, H., et al. (1992) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(13)80002-9 · Cited by 540 · cited 1×
“Others have also reported the association between a low albumin and an increase in graft thrombosis (36,38).”
BackgroundSelf-citationPrevention of hemodialysis fistula thrombosis. Early detection of venous stenoses
Schwab, S. J., Raymond, J. R., Saeed, M., Newman, G. E., Dennis, P. A., & Bollinger, R. R. (1989) · Kidney International · doi:10.1038/ki.1989.250 · Cited by 426
Reporting Standards for Percutaneous Interventions in Dialysis Access
Gray, R. J., Sacks, D., Martin, L. G., & Trerotola, S. O. (2003) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000094618.61428.58 · Cited by 390 · cited 2×
“PTA was performed by means of standard techniques (26).”
MethodTheory and validation of access flow measurement by dilution technique during hemodialysis
Krivitski, N. M. (1995) · Kidney International · doi:10.1038/ki.1995.290 · Cited by 327
Vascular access blood flow monitoring reduces access morbidity and costs
McCarley, P. B., Wingard, R. L., Shyr, Y., Pettus, W., Hakim, R. M., & Ikizler, T. A. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.0600031164.x · Cited by 283
Besarab, A., Sullivan, K. L., Ross, R. P., & Moritz, M. J. (1995) · Kidney International · doi:10.1038/ki.1995.192 · Cited by 279 · cited 2×
“Pump flow, needle size and position, and BP (8) may alter the DVP, and this variation was minimized by performing DVP at a standard pump flow of 200 ml/min with 15-gauge needles and performing the measurement within the first 5 min of initiating the dialysis treatment.”
BackgroundMethodPredictive measures of vascular access thrombosis: A prospective study
May, R. E., Himmelfarb, J., Yenicesu, M., Knights, S., Ikizler, T. A., Schulman, G., Hernanz‐Schulman, M., Shyr, Y., & Hakim, R. M. (1997) · Kidney International · doi:10.1038/ki.1997.499 · Cited by 274
Cited by
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Self-citationSchmidli, J., Widmer, M. K., Basile, C., de Donato, G., Gallieni, M., Gibbons, C. P., Haage, P., Hamilton, G., Hedin, U., Kamper, L., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.02.001 · Cited by 878
Sidawy, A. N., Spergel, L. M., Besarab, A., Allon, M., Jennings, W. C., Padberg, F. T., Murad, M. H., Montori, V. M., O'Hare, A. M., Calligaro, K. D., et al. (2008) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2008.08.042 · Cited by 553
Fistula First Initiative: Advantages and Pitfalls
Lok, C. E. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01080307 · Cited by 338
Current Management of Vascular Access
Allon, M. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00860207 · Cited by 289
Complications of arteriovenous hemodialysis access: Recognition and management
Padberg, F. T., Calligaro, K. D., & Sidawy, A. N. (2008) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2008.08.067 · Cited by 270
Manns, B., Tonelli, M., Yilmaz, S., Lee, H., Laupland, K., Klarenbach, S., Radkevich, V., & Murphy, B. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004050355 · Cited by 237
“However, a randomized study that compared the utility of ultrasound screening with dynamic venous pressure monitoring in synthetic grafts showed no difference in graft survival but higher use of resources among patients who were randomized to ultrasound dilution monitoring (21).”
BackgroundKukita, K., Ohira, S., Amano, I., Naito, H., Azuma, N., Ikeda, K., Kanno, Y., Satou, T., Sakai, S., Sugimoto, T., et al. (2015) · Therapeutic Apheresis and Dialysis · doi:10.1111/1744-9987.12296 · Cited by 211
Ohira, S., Naito, H., Amano, I., Azuma, N., Ikeda, K., Kukita, K., Goto, Y., Sakai, S., Shinzato, T., Sugimoto, T., et al. (2006) · Therapeutic Apheresis and Dialysis · doi:10.1111/j.1744-9987.2006.00410.x · Cited by 201
Ultrasound Monitoring to Detect Access Stenosis in Hemodialysis Patients: A Systematic Review
Tonelli, M., James, M., Wiebe, N., Jindal, K., & Hemmelgarn, B. (2008) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2007.11.025 · Cited by 175
Metadata
- Authors
- Moist, L. M., Churchill, D. N., House, A. A., Millward, S. F., Elliott, J. E., Kribs, S. W., DeYoung, W. J., Blythe, L., Stitt, L. W., & Lindsay, R. M.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2003-10
- Volume
- 14
- Issue
- 10
- Pages
- 2645-2653
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2123803594
- Cited by
- 212
- References
- 25
- FWCI
- 24.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.