The DOI matches its Crossref record.
Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed Tomography
Abstract
The purpose of the current study was to evaluate whether safe acetabular component position depends on differences in pelvic location between the supine, standing, and sitting positions. The subjects of the current study were 101 patients who had total hip arthroplasty. Anteroposterior radiographs of the pelvis with the patients in the supine, standing, and sitting positions were obtained preoperatively and 1 year after total hip arthroplasty. Computed tomography images of the pelvis were obtained preoperatively. Using image matching between the three-dimensional computed tomography model and anteroposterior radiograph, pelvic flexion angles with the patient in the supine, standing, and sitting positions were calculated. The mean preoperative pelvic flexion angle was 5 degrees +/- 9 degrees (range, -37 degrees -30 degrees ) in the supine position, 3 degrees +/- 12 degrees (range, -46 degrees -33 degrees ) in the standing position, and -29 degrees +/- 12 degrees (range, -62 degrees -10 degrees ) in the sitting position. Because there was much intersubject variability in pelvic flexion angle, it is not appropriate to determine orientation of the acetabular component from anatomic landmarks. In 90% of the cases, the difference in pelvic flexion angle between the supine and standing positions preoperatively was 10 degrees or less. In 90% of the cases, there was 20 degrees or greater extension of the pelvis from the supine position to the sitting position preoperatively, and the safe range of flexion of the hip from anterior prosthetic impingement in the sitting position was 20 degrees or greater than that in the supine position. Preoperative pelvic position in each case was almost completely maintained 1 year after total hip arthroplasty. It is reasonable to regard the pelvic position in the supine position as the functional pelvic position and proper pelvic reference frame in determining optimal orientation of the acetabular component in 90% of cases before and 1 year after total hip arthroplasty, although an adjustment of orientation of the acetabular component was needed for the remaining cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jamali, A. A., Mladenov, K., Meyer, D. C., Martinez, A., Beck, M., Ganz, R., & Leunig, M. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20380 · Cited by 375
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Self-citation
Metadata
- Authors
- Nishihara, S., Sugano, N., Nishii, T., Ohzono, K., & Yoshikawa, H.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2003-06
- Volume
- 411
- Issue
- 411
- Pages
- 140-151
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2001732080
- Cited by
- 251
- References
- 0
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed Tomography. https://app.cochat.ai/papers/10.1097/01.blo.0000069891.31220.fd
- The paper
- Nishihara, S., Sugano, N., Nishii, T., Ohzono, K., & Yoshikawa, H. (2003). Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed Tomography. Clinical Orthopaedics & Related Research. https://doi.org/10.1097/01.blo.0000069891.31220.fd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.