The DOI matches its Crossref record.
Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty
Abstract
Successful total knee arthroplasty is dependent on the correct alignment of implanted prostheses. Major clinical problems can be related to poor femoral component positioning, including sagittal plane and rotational malalignment. A prospective randomized study was designed to test whether an optical navigation system for total knee arthroplasty achieved greater implantation precision than a nonnavigated technique. The primary variable was rotation of the femoral component in the transverse plane, measured from postoperative radiographs and computed tomography images. Sixty-four patients were included in the study. All patients received the Duracon total knee prosthesis. The patients were randomly divided into two groups: Group C patients had conventional total knee arthroplasty without navigation; Group N patients had total knee arthroplasty using a computer-assisted knee navigation system. Analysis showed that patients in Group N had significantly better rotational alignment and flexion angle of the femoral component than patients in Group C. In addition, superior postoperative alignment of the mechanical axis, posterior tibial slope, and rotational alignment was achieved for patients in Group N. The use of a navigation system provides improved alignment accuracy, and can help to avoid femoral malrotation and errors in axial alignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Choong, P. F., Dowsey, M. M., & Stoney, J. D. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.02.018 · Cited by 447
Howell, S. M., Kuznik, K., Hull, M. L., & Siston, R. A. (2008) · Orthopedics · doi:10.3928/01477447-20080901-15 · Cited by 288
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Metadata
- Authors
- St??ckl, B., Nogler, M., Rosiek, R., Fischer, M., Krismer, M., & Kessler, O.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2004-09
- Volume
- 426
- Issue
- 426
- Pages
- 180-186
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2020648651
- Cited by
- 286
- References
- 0
- FWCI
- 21.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty. https://app.cochat.ai/papers/10.1097/01.blo.0000136835.40566.d9
- The paper
- St??ckl, B., Nogler, M., Rosiek, R., Fischer, M., Krismer, M., & Kessler, O. (2004). Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/01.blo.0000136835.40566.d9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.