Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 340

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Staged Management of High-Energy Proximal Tibia Fractures (OTA Types 41): The Results of a Prospective, Standardized Protocol

Egol, Kenneth A, Tejwani, Nirmal C, Capla, Edward L, Wolinsky, Philip L, Koval, Kenneth J·2005·Journal of Orthopaedic Trauma

Abstract

OBJECTIVES: This study evaluated the use of a staged protocol involving temporary spanning external fixation and delayed formal definitive fixation in the management of high-energy proximal tibia fractures (OTA types 41) with regard to soft-tissue management, development of complications, and functional outcomes. SETTING: Two level-one trauma centers and a tertiary care orthopaedic center. PATIENTS: Fifty-three patients with 57 high-energy tibial plateau fractures. METHODS: The authors instituted a protocol of immediate placement of knee spanning external fixation with management of soft-tissue injuries for all high-energy proximal tibia fractures. Between August 1999 and May 2002, 62 consecutive patients with 67 high-energy proximal tibia fractures (OTA types 41A, B, C) underwent temporary knee spanning external fixation on the day of admission. Nine patients with 10 fractures who transferred care after initial stabilization or sustained an extraarticular fracture were excluded. The remaining 53 patients with 57 fractures underwent repair of articular fractures and meta-diaphyseal fracture repair with plates and screw constructs or conversion to a ring fixator. These patients had a mean age of 47 years (standard deviation (SD), 14). Of these 53 patients, 42 (79%) were men and 11 (21%) were women. Characteristics of the 57 fractures were: 42 Schatzker VI (74%), 12 Schatzker V (21%), 2 Schatzker IV (4%), and 1 Schatzker II (2%). There were 41 closed fractures and 16 open fractures. (One patient had bilateral fractures with 1 extremity open and 1 closed). Orthopaedic evaluation at latest follow-up included a clinical and radiographic examination and functional outcome measurement with the Western Ontario McMaster functional knee score (WOMAC). Eight patients with 8 fractures were lost to follow-up. This left 45 patients with 49 fractures with a mean follow-up of 15.7 (SD, 5.7; range, 8-40) months. RESULTS: Complications included 3 (5%) deep wound infections, 2 (4%) nonunions, and 2 patients (4%) with significant knee stiffness (<90 degrees). Nine patients (16%) underwent additional surgery after definitive skeletal stabilization related to their injury. Range of knee motion at final follow-up was 1 degrees (SD, 4) to 106 degrees (SD, 15). The mean WOMAC was 91 (SD, 55). Poor results did not correlate with demographic or injury characteristics. DISCUSSION: We had a relatively low rate of wound infection in these complex injuries (5% overall). There was only 1 wound problem in our subset of patients with closed fractures and 2 infections in those with open fractures. One downside of this technique may be residual knee stiffness. The benefits of temporizing spanning external fixation include osseous stabilization, access to soft tissues, and prevention of further articular damage. Our relatively low rates of complications in patients who sustain high-energy proximal tibia fractures and the access this technique affords in open fractures and those with compartment syndrome lead us to recommend this technique in all high-energy intra-articular and extra-articular fractures of the proximal tibia. CLINICAL RELEVANCE: This study supports the practice of delayed internal fixation until the soft-tissue envelope allows for definitive fixation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.bot.0000171881.11205.80

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 340

Metadata

Authors
Egol, K. A., Tejwani, N. C., Capla, E. L., Wolinsky, P. L., & Koval, K. J.
Venue
Journal of Orthopaedic Trauma
Published
2005-08
Volume
19
Issue
7
Pages
448-455
ISSN
0890-5339 (ISSN-L)
OpenAlex
W2072219868
Cited by
340
References
8
FWCI
4.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Staged Management of High-Energy Proximal Tibia Fractures (OTA Types 41): The Results of a Prospective, Standardized Protocol. https://app.cochat.ai/papers/10.1097/01.bot.0000171881.11205.80
The paper
Egol, K. A., Tejwani, N. C., Capla, E. L., Wolinsky, P. L., & Koval, K. J. (2005). Staged Management of High-Energy Proximal Tibia Fractures (OTA Types 41): The Results of a Prospective, Standardized Protocol. Journal of Orthopaedic Trauma. https://doi.org/10.1097/01.bot.0000171881.11205.80

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.