Transmissibility of 15-Hertz to 35-Hertz Vibrations to the Human Hip and Lumbar Spine: Determining the Physiologic Feasibility of Delivering Low-Level Anabolic Mechanical Stimuli to Skeletal Regions at Greatest Risk of Fracture Because of Osteoporosis
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: Experiments were undertaken to determine the degree to which high-frequency (15-35 Hz) ground-based, whole-body vibration are transmitted to the proximal femur and lumbar vertebrae of the standing human. OBJECTIVES: To establish if extremely low-level (<1 g, where 1 g = earth's gravitational field, or 9.8 ms-2) mechanical stimuli can be efficiently delivered to the axial skeleton of a human. SUMMARY OF BACKGROUND DATA: Vibration is most often considered an etiologic factor in low back pain as well as several other musculoskeletal and neurovestibular complications, but recent in vivo experiments in animals indicates that extremely low-level mechanical signals delivered to bone in the frequency range of 15 to 60 Hz can be strongly anabolic. If these mechanical signals can be effectively and noninvasively transmitted in the standing human to reach those sites of the skeleton at greatest risk of osteoporosis, such as the hip and lumbar spine, then vibration could be used as a unique, nonpharmacologic intervention to prevent or reverse bone loss. MATERIALS AND METHODS: Under sterile conditions and local anesthesia, transcutaneous pins were placed in the spinous process of L4 and the greater trochanter of the femur of six volunteers. Each subject stood on an oscillating platform and data were collected from accelerometers fixed to the pins while a vibration platform provided sinusoidal loading at discrete frequencies from 15 to 35 Hz, with accelerations ranging up to 1 g(peak-peak). RESULTS: With the subjects standing erect, transmissibility at the hip exceeded 100% for loading frequencies less than 20 Hz, indicating a resonance. However, at frequencies more than 25 Hz, transmissibility decreased to approximately 80% at the hip and spine. In relaxed stance, transmissibility decreased to 60%. With 20-degree knee flexion, transmissibility was reduced even further to approximately 30%. A phase-lag reached as high as 70 degrees in the hip and spine signals. CONCLUSIONS: These data indicate that extremely low-level, high-frequency mechanical accelerations are readily transmitted into the lower appendicular and axial skeleton of the standing individual. Considering the anabolic potential of exceedingly low-level mechanical signals in this frequency range, this study represents a key step in the development of a biomechanically based treatment for osteoporosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-02730-5 · Cited by 1,759
Low mechanical signals strengthen long bones
Rubin, C., Turner, A. S., Bain, S., Mallinckrodt, C., & McLeod, K. (2001) · Nature · doi:10.1038/35088122 · Cited by 718 · cited 1×
“Thus, if such low-level mechanical signals can be effectively delivered to the axial and appendicular skeleton, perhaps through whole-body vibration, a unique biomechanical prophylaxis for osteoporosis may be possible.(14)”
BackgroundSelf-citationMenopausal Hormone Replacement Therapy and Risk of Ovarian Cancer
Lacey, Jr. (2002) · JAMA · doi:10.1001/jama.288.3.334 · Cited by 606
Perspectives: How many women have osteoporosis now?
Dr. Melton, J. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100202 · Cited by 595 · cited 1×
“5 standard deviations of young normal values.(5) Certainly, in devising intervention strategies for this disease, slowing the loss of bone in the recent postmenopausal population, as well as reversing bone loss in the osteoporotic person, will have a significant and beneficial impact on reduction of fractures and asso…”
BackgroundRubin, C., Recker, R., Cullen, D., Ryaby, J., McCabe, J., & McLeod, K. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.0301251 · Cited by 592
Self-citationLow Magnitude Mechanical Loading Is Osteogenic in Children With Disabling Conditions
Ward, K., Alsop, C., Caulton, J., Rubin, C., Adams, J., & Mughal, Z. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040129 · Cited by 432
Self-citationFritton, S. P., J. McLeod, K., & Rubin, C. T. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00210-9 · Cited by 401 · cited 1×
“Importantly, these higher frequency mechanical signals, although small, are physiologic in nature, as they arise from the contractions of adjacent musculature,(35) and thus signify a persistent low-level, dynamic mechanical signal to the bone tissue.(36) Considering the anabolic nature of low-level vibration, determin…”
BackgroundSelf-citationEnsrud, K. E., Palermo, L., Black, D. M., Cauley, J., Jergas, M., Orwoll, E. S., Nevitt, M. C., Fox, K. M., & Cummings, S. R. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650101122 · Cited by 358
Rubin, C., Turner, A. S., Müller, R., Mittra, E., McLeod, K., Lin, W., & Qin, Y.-X. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.2.349 · Cited by 328
Self-citation
Cited by
Vibration as an exercise modality: how it may work, and what its potential might be
Rittweger, J. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1303-3 · Cited by 863
Rubin, C., Recker, R., Cullen, D., Ryaby, J., McCabe, J., & McLeod, K. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.0301251 · Cited by 592
Self-citationWhole body vibration exercise: are vibrations good for you?
Cardinale, M., & Wakeling, J. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.016857 · Cited by 483
Mechanical signals as anabolic agents in bone
Ozcivici, E., Luu, Y. K., Adler, B., Qin, Y.-X., Rubin, J., Judex, S., & Rubin, C. T. (2010) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2009.239 · Cited by 441
Self-citationLow Magnitude Mechanical Loading Is Osteogenic in Children With Disabling Conditions
Ward, K., Alsop, C., Caulton, J., Rubin, C., Adams, J., & Mughal, Z. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040129 · Cited by 432
Self-citationGilsanz, V., Wren, T. A., Sanchez, M., Dorey, F., Judex, S., & Rubin, C. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060612 · Cited by 370
Self-citationGusi, N., Raimundo, A., & Leal, A. (2006) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-7-92 · Cited by 317
Vibration Exercise: The Potential Benefits
Cochrane, D. J. (2011) · International Journal of Sports Medicine · doi:10.1055/s-0030-1268010 · Cited by 248
“Rubin [109] found that at low vibration frequency the vibration transmission to the hip was dissipated; however, when the frequency was raised to 15 – 35 Hz, a higher response at the hip was evident.”
Prisby, R. D., Lafage-Proust, M.-H., Malaval, L., Belli, A., & Vico, L. (2008) · Ageing Research Reviews · doi:10.1016/j.arr.2008.07.004 · Cited by 240
“All rights reserved. doi:10.1016/j.arr.2008.07.004 skeleton (Rubin et al., 2003) to elicit increased bone mass.”
InfluentialTransmission of Vertical Whole Body Vibration to the Human Body
Kiiski, J., Heinonen, A., Järvinen, T. L., Kannus, P., & Sievänen, H. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080315 · Cited by 233
Osteocyte Mechanobiology and Pericellular Mechanics
Jacobs, C. R., Temiyasathit, S., & Castillo, A. B. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105302 · Cited by 197
Effect of whole-body vibration on BMD: a systematic review and meta-analysis
Slatkovska, L., Alibhai, S. M. H., Beyene, J., & Cheung, A. M. (2010) · Osteoporosis International · doi:10.1007/s00198-010-1228-z · Cited by 183
“Through ground-based vertical accelerations starting at the plantar surface of the feet, the mechanical vibration is transmitted through the weightbearing muscles and bones [15, 16].”
BackgroundGarman, R., Gaudette, G., Donahue, L., Rubin, C., & Judex, S. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20354 · Cited by 166
Self-citationBemben, D. A., Palmer, I. J., Bemben, M. G., & Knehans, A. W. (2010) · Bone · doi:10.1016/j.bone.2010.06.019 · Cited by 111
“Theoretically, some of the vibration signal is lost at the spine and hip when standing on the platform; and transmission of the signal is also affected by how the person stands on the platform, with greater amounts of flexion causing a greater loss of the signal to the hip and spine [36].”
Background
Metadata
- Authors
- Rubin, C., Pope, M., Chris Fritton, J., Magnusson, M., Hansson, T., & McLeod, K.
- Venue
- Spine
- Published
- 2003-12
- Volume
- 28
- Issue
- 23
- Pages
- 2621-2627
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2134028135
- Cited by
- 234
- References
- 32
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.