A Prospective, Randomized Controlled Clinical Trial of Anterior Lumbar Interbody Fusion Using a Titanium Cylindrical Threaded Fusion Device
The DOI matches its Crossref record.
Abstract
STUDY DESIGN: A prospective, randomized, controlled clinical trial comparing a cylindrical threaded titanium cage to a femoral ring allograft control for anterior lumbar interbody fusion. OBJECTIVE: To compare these two implants with regard to arthrodesis. Secondary outcome measures included pain relief, neurological status, and general health status. SUMMARY OF BACKGROUND DATA: Anterior lumbar interbody fusion is a well-accepted procedure using trapezoidal femoral ring allografts or cylindrical titanium cages. Clinical and biomechanical studies evaluating these two distinct constructs are numerous; however, no prospective, randomized study comparing them has been done. METHODS: A multicenter trial of 140 patients: 78 were randomized to the cylindrical threaded titanium cage device treatment arm and 62 patients randomized into the control group. All had autogenous iliac crest bone graft packed into the device. All patients had a single-level stand-alone anterior lumbar interbody fusion at either the L4-L5 or L5-S1 interspace for symptomatic degenerative disc disease. Radiographic fusion data were collected as well as multiple types of outcome data, including pain/disability scores, neurologic status, and overall health. RESULTS: At 12 months, 97% of the cylindrical threaded titanium cage device group and 40% of the control group demonstrated radiographic fusion. At 24 months, 97% of the cylindrical threaded titanium cage group and 52% of the control group showed radiographic fusion. These fusion rate differences are statistically significant (P < 0.001). The Oswestry and neurologic scores were not significantly different between groups. DISCUSSION: This is the first prospective, randomized, multicenter clinical trial that compares fusion cage results to control data. CONCLUSION: Cylindrical threaded titanium cages have a higher fusion rate, comparable improvements in clinical outcome (Oswestry, Low Back Pain Questionnaire, SF-36), and fewer secondary supplemental fixation procedures compared to the femoral ring allograft control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chapter 4 European guidelines for the management of chronic nonspecific low back pain
Airaksinen, O., Brox, J. I., Cedraschi, C., Hildebrandt, J., Klaber-Moffett, J., Kovacs, F., Mannion, A. F., Reis, S., Staal, J. B., Ursin, H., et al. (2006) · European Spine Journal · doi:10.1007/s00586-006-1072-1 · Cited by 2,594
Carragee, E. J., Hurwitz, E. L., & Weiner, B. K. (2011) · The Spine Journal · doi:10.1016/j.spinee.2011.04.023 · Cited by 1,395
A Review of the Clinical Side Effects of Bone Morphogenetic Protein-2
James, A. W., LaChaud, G., Shen, J., Asatrian, G., Nguyen, V., Zhang, X., Ting, K., & Soo, C. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0357 · Cited by 1,131
Chou, R., Baisden, J., Carragee, E. J., Resnick, D. K., Shaffer, W. O., & Loeser, J. D. (2009) · Spine · doi:10.1097/brs.0b013e3181a105fc · Cited by 456
Surgery for Degenerative Lumbar Spondylosis: Updated Cochrane Review
Gibson, J. N. A., & Waddell, G. (2005) · Spine · doi:10.1097/01.brs.0000182315.88558.9c · Cited by 354
Metadata
- Authors
- Sasso, R. C., Kitchel, S. H., & Dawson, E. G.
- Venue
- Spine
- Published
- 2004-01
- Volume
- 29
- Issue
- 2
- Pages
- 113-121
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2004467703
- Cited by
- 136
- References
- 0
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Prospective, Randomized Controlled Clinical Trial of Anterior Lumbar Interbody Fusion Using a Titanium Cylindrical Threaded Fusion Device. https://app.cochat.ai/papers/10.1097/01.brs.0000107007.31714.77
- The paper
- Sasso, R. C., Kitchel, S. H., & Dawson, E. G. (2004). A Prospective, Randomized Controlled Clinical Trial of Anterior Lumbar Interbody Fusion Using a Titanium Cylindrical Threaded Fusion Device. Spine. https://doi.org/10.1097/01.brs.0000107007.31714.77
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.