Analysis of Operative Complications in a Series of 471 Anterior Lumbar Interbody Fusion Procedures
Abstract
In Brief Study Design. This retrospective review compares the intraoperative and perioperative complications associated with the placement of threaded devices and nonthreaded devices used in anterior lumbar interbody fusions. Objective. Anterior lumbar interbody fusion is a common procedure performed with either a nonthreaded device, such as a femoral ring, or a threaded device, such as with a cage or a bone dowel. Summary of Background Data. Many studies have been done detailing the fusion rates and biomechanical properties of both devices. However, few studies have been performed evaluating acute complications between the two device types. Methods. A retrospective chart review was performed of 471 consecutive patients who underwent anterior lumbar interbody fusion: 243 with a nonthreaded interbody device and 228 with a threaded interbody device. Operative notes, anesthesia reports, discharge summaries, and follow-up notes were reviewed from 1992 to June 2002. The patients' demographics, diagnosis, number of levels fused, type of device used, length of hospital stay, and acute complications, either intraoperative or perioperative, were collected and analyzed. Results. Approximately 4.8% of patients with a threaded type interbody device had an intraoperative complication whereas only 0.4% of patients with a nonthreaded type device had an intraoperative complication. There was a significant association between interbody device type (threaded vs. nonthreaded) and occurrence of an intraoperative complication (P = 0.0024). Conclusions. Placement of threaded devices, such as cages or bone dowels, was associated with a higher acute complication rate than was the placement of nonthreaded devices during anterior lumbar interbody fusion. Of 471 consecutive patients who underwent anterior lumbar interbody fusion, 4.8% of patients with a threaded type interbody device had an intraoperative complication whereas only 0.4% of patients with a nonthreaded type device had an intraoperative complication. There was a significant association between interbody device type (threaded vs. nonthreaded) and occurrence of an intraoperative complication (P = 0.0024).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carragee, E. J., Hurwitz, E. L., & Weiner, B. K. (2011) · The Spine Journal · doi:10.1016/j.spinee.2011.04.023 · Cited by 1,395
A Review of the Clinical Side Effects of Bone Morphogenetic Protein-2
James, A. W., LaChaud, G., Shen, J., Asatrian, G., Nguyen, V., Zhang, X., Ting, K., & Soo, C. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0357 · Cited by 1,131
Minimally Invasive Surgery: Lateral Approach Interbody Fusion: Results and Review
Youssef, J. A., McAfee, P. C., Patty, C. A., Raley, E., DeBauche, S., Shucosky, E., & Chotikul, L. (2010) · Spine · doi:10.1097/brs.0b013e3182023438 · Cited by 279
Metadata
- Authors
- Sasso, R. C., Best, N. M., Mummaneni, P. V., Reilly, T. M., & Hussain, S. M.
- Venue
- Spine
- Published
- 2005-03
- Volume
- 30
- Issue
- 6
- Pages
- 670-674
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2084692212
- Cited by
- 193
- References
- 0
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of Operative Complications in a Series of 471 Anterior Lumbar Interbody Fusion Procedures. https://app.cochat.ai/papers/10.1097/01.brs.0000155423.18218.75
- The paper
- Sasso, R. C., Best, N. M., Mummaneni, P. V., Reilly, T. M., & Hussain, S. M. (2005). Analysis of Operative Complications in a Series of 471 Anterior Lumbar Interbody Fusion Procedures. Spine. https://doi.org/10.1097/01.brs.0000155423.18218.75
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.