Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 423

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation*

Bakhtiari, Kamran, Meijers, Joost C.M., de Jonge, Evert, Levi, Marcel·2004·Critical Care Medicine

Abstract

OBJECTIVES: A diagnosis of disseminated intravascular coagulation (DIC) is hampered by the lack of an accurate diagnostic test. Based on the retrospective analysis of studies in patients with DIC, a scoring system (0-8 points) using simple and readily available routine laboratory tests has been proposed. The aim of this study was to prospectively validate this scoring system and assess its feasibility, sensitivity, and specificity in a consecutive series of intensive care patients. DESIGN: Prospective cohort of intensive care patients. SETTING: Adult intensive care unit in a tertiary academic center. PATIENTS: Consecutive patients with a clinical suspicion of disseminated intravascular coagulation. INTERVENTIONS: Patients were followed during their admission to the intensive care unit, and the DIC score was calculated every 48 hrs and compared with a "gold standard" based on expert opinion. In addition, an activated partial thromboplastin time (aPTT) waveform analysis, which has been reported to be a good predictor for the absence or presence of DIC, was performed. MEASUREMENTS AND MAIN RESULTS: We analyzed 660 samples from 217 consecutive patients. The prevalence of DIC was 34%. There was a strong correlation between an increasing DIC score and 28-day mortality (for each 1-point increment in the DIC score, the odds ratio for mortality was 1.25). The sensitivity of the DIC score was 91% and the specificity 97%. An abnormal aPTT waveform was seen in 32% of patients and correlated well with the presence of DIC (sensitivity 88%, specificity 97%). In 19% of patients, the aPTT waveform-based diagnosis of DIC preceded the diagnosis based on the scoring system. CONCLUSIONS: A diagnosis of DIC based on a simple scoring system, using widely available routine coagulation tests, is sufficiently accurate to make or reject a diagnosis of DIC in intensive care patients with a clinical suspicion of this condition. An aPTT waveform analysis is an interesting and promising tool to assist in the diagnostic management of DIC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000147769.07699.e3

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 423

Metadata

Authors
Bakhtiari, K., Meijers, J. C. M., de Jonge, E., & Levi, M.
Venue
Critical Care Medicine
Published
2004-12
Volume
32
Issue
12
Pages
2416-2421
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2020513354
Cited by
423
References
20
FWCI
10.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation*. https://app.cochat.ai/papers/10.1097/01.ccm.0000147769.07699.e3
The paper
Bakhtiari, K., Meijers, J. C. M., de Jonge, E., & Levi, M. (2004). Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000147769.07699.e3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.