Ultrasound diagnosis of occult pneumothorax*
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Pneumothorax can be missed by bedside radiography, and computed tomography is the current alternative. We asked whether lung ultrasound could be of any help in this situation. DESIGN: Retrospective study. SETTING: The medical intensive care unit of a university-affiliated teaching hospital. PATIENTS: All patients admitted to the intensive care unit are routinely scanned with whole-body ultrasound (including screening for pneumothorax) and chest radiography. The study population included 200 consecutive undifferentiated intensive care unit patients who received a chest computed tomography scan in addition to ultrasound and chest radiograph. Forty-seven consecutive cases of radioccult pneumothorax were compared with 310 consecutive hemithoraces free from pneumothorax in the intensive care unit. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: Three signs were investigated at the anterolateral chest wall in supine patients: lung sliding, the A line sign, and the lung point. A total of 357 hemithoraces were analyzed in this study, 47 with occult pneumothorax and 310 controls. Four of the 47 cases of pneumothorax were excluded from the final analysis (parietal emphysema) as well as eight of the 310 controls (large dressings), leaving a final study population of 345 hemithoraces in 197 patients. Feasibility was 98%. Ultrasound scans in all 43 examinable patients with pneumothorax showed absent lung sliding, 41 of 43 patients had the A line sign, and 34 exhibited a lung point. Among 302 analyzable controls, 65 had absent lung sliding, 16 of them showed an A line sign, and none showed a lung point. For the diagnosis of occult pneumothorax, the abolition of lung sliding alone had a sensitivity of 100% and a specificity of 78%. Absent lung sliding plus the A line sign had a sensitivity of 95% and a specificity of 94%. The lung point had a sensitivity of 79% and a specificity of 100%. CONCLUSIONS: For the diagnosis of occult pneumothorax, ultrasound can decrease the need for computed tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 1×
“Computed tomography (CT), the current gold standard, solves this problem but introduces major drawbacks (transfer of critically ill patients, delay, irradiation, and cost, among others), whereas the excessive search for pneumothorax has similar drawbacks (12).”
BackgroundLichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077
Self-citationThe Comet-tail Artifact: An Ultrasound Sign of Alveolar-Interstitial Syndrome
LICHTENSTEIN, D., MÉZIÈRE, G., BIDERMAN, P., GEPNER, A., & BARRÉ, O. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.5.96-07096 · Cited by 1,075
Self-citationYearbook of Intensive Care and Emergency Medicine 2002
(2002) · Springer eBooks · doi:10.1007/978-3-642-56011-8 · Cited by 876
A Bedside Ultrasound Sign Ruling Out Pneumothorax in the Critically III
Lichtenstein, D. A., & Menu, Y. (1995) · Chest · doi:10.1378/chest.108.5.1345 · Cited by 787
Self-citationSahn, S. A., & Heffner, J. E. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003233421207 · Cited by 674
Ultrasound diagnosis of alveolar consolidation in the critically ill
Lichtenstein, D. A., Lascols, N., Mezière, G., & Gepner, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2075-6 · Cited by 512
Self-citationThe comet-tail artifact: an ultrasound sign ruling out pneumothorax
Lichtenstein, D., Mezière, G., Biderman, P., & Gepner, A. (1999) · Intensive Care Medicine · doi:10.1007/s001340050862 · Cited by 466
Self-citationLichtenstein, D., & Mezière, G. (1998) · Intensive Care Medicine · doi:10.1007/s001340050771 · Cited by 412
Self-citationDistribution of pneumothorax in the supine and semirecumbent critically ill adult
Tocino, I., Miller, M., & Fairfax, W. (1985) · American Journal of Roentgenology · doi:10.2214/ajr.144.5.901 · Cited by 296
Ultrasound diagnosis of an acute dyspnea
Lichtenstein, D. A., & Mezière, G. A. (2003) · Critical Care · doi:10.1186/cc2078 · Cited by 273
Self-citationRantanen, N. W. (1986) · Veterinary Clinics of North America Equine Practice · doi:10.1016/s0749-0739(17)30732-0 · Cited by 132
Risk factors for the misdiagnosis of pneumothorax in the intensive care unit
Kollef, M. H. (1991) · Critical Care Medicine · doi:10.1097/00003246-199107000-00014 · Cited by 76
Kirkpatrick, A. W., Ng, A., Dulchavsky, S. A., Lyburn, I., Harris, A. C., Torregianni, W., Simons, R. K., & Nicolaou, S. (2001) · doi:10.1097/00005373-200104000-00029 · Cited by 75
Lung ultrasound in the critically ill
Lichtenstein, D. A. (2005) · Clinical Intensive Care · doi:10.3109/09563070500131027 · Cited by 30
Self-citation
Cited by
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068
Self-citationLung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 711
Self-citationBLUE-Protocol and FALLS-Protocol
Lichtenstein, D. A. (2015) · Chest · doi:10.1378/chest.14-1313 · Cited by 691
Self-citationCopetti, R., Soldati, G., & Copetti, P. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-16 · Cited by 555
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Metadata
- Authors
- Lichtenstein, D. A., Mezière, G., Lascols, N., Biderman, P., Courret, J.-P., Gepner, A., Goldstein, I., & Tenoudji-Cohen, M.
- Venue
- Critical Care Medicine
- Published
- 2005-06
- Volume
- 33
- Issue
- 6
- Pages
- 1231-1238
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2161590196
- Cited by
- 632
- References
- 15
- FWCI
- 12.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.