The DOI matches its Crossref record.
Decompression of the left atrium during extracorporeal membrane oxygenation using a transseptal cannula incorporated into the circuit*
Abstract
OBJECTIVES: When extracorporeal membrane oxygenation (ECMO) is used in the setting of severe myocardial dysfunction, left ventricular end-diastolic and left atrial pressure can rise to extremely high levels. Decompression of the left atrium in this setting is essential for resolution of pulmonary edema and recovery of left ventricular function. We sought to evaluate whether adequate left atrial decompression can be achieved via percutaneous placement of a transseptal left atrial drain incorporated in the ECMO venous circuit. DESIGN: Retrospective case series. SETTING: Tertiary care center pediatric intensive care unit and cardiac catheterization laboratory. PATIENTS: Seven patients (age 8 months to 28 yrs) with cardiac failure on venoarterial ECMO with left atrial hypertension. INTERVENTIONS: All patients underwent left atrial decompression with transseptal puncture and placement of a drain (8- to 15-Fr) incorporated into the ECMO venous circuit. Catheterization and ECMO records and echocardiograms were reviewed, as were the clinical course and outcome for each patient. MEASUREMENTS AND MAIN RESULTS: The median time from ECMO cannulation to left atrial decompression was 11 hrs. Average initial left atrial pressure was 31 mm Hg. Successful drain placement was achieved in seven patients with no major procedural complications. Echocardiographic improvement in left atrial dilation was achieved in five patients (71%). Inability to decompress the left atrium was fatal in two patients. Four patients were decannulated (57%), and three survived to hospital discharge (43%). Larger sheath size and higher flow rate correlated with a greater likelihood of success. CONCLUSIONS: Adequate decompression of the left atrium can be achieved by transseptal placement of a left atrial drain incorporated into the ECMO circuit. This technique represents a reasonable alternative to blade or balloon atrial septostomy for patients requiring left atrial decompression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Extra Corporeal Membrane Oxygenation (ECMO) review of a lifesaving technology.
Makdisi, G., & Wang, I. (2015) · PubMed · doi:10.3978/j.issn.2072-1439.2015.07.17 · Cited by 574
Pappalardo, F., Schulte, C., Pieri, M., Schrage, B., Contri, R., Soeffker, G., Greco, T., Lembo, R., Müllerleile, K., Colombo, A., et al. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.668 · Cited by 520
The state of the art in extracorporeal membrane oxygenation
Pujara, D., Sandoval, E., Simpson, L., Mallidi, H. R., & Singh, S. K. (2015) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/j.semtcvs.2015.02.004 · Cited by 19
Metadata
- Authors
- Aiyagari, R. M., Rocchini, A. P., Remenapp, R. T., & Graziano, J. N.
- Venue
- Critical Care Medicine
- Published
- 2006-10
- Volume
- 34
- Issue
- 10
- Pages
- 2603-2606
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2095253573
- Cited by
- 200
- References
- 0
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Decompression of the left atrium during extracorporeal membrane oxygenation using a transseptal cannula incorporated into the circuit*. https://app.cochat.ai/papers/10.1097/01.ccm.0000239113.02836.f1
- The paper
- Aiyagari, R. M., Rocchini, A. P., Remenapp, R. T., & Graziano, J. N. (2006). Decompression of the left atrium during extracorporeal membrane oxygenation using a transseptal cannula incorporated into the circuit*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000239113.02836.f1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.