Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654 · cited 1×
“T he recognition that mechanical ventilation can in itself induce or worsen previous lung injury has challenged the traditional view on positive end-expiratory pressure (PEEP) as a mere adjuvant for improving oxygenation (1).”
Background(2004) · New England Journal of Medicine · doi:10.1056/nejmoa032193 · Cited by 2,565
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure
Suter, P. M., Fairley, H. B., & Isenberg, M. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197502062920604 · Cited by 1,295
Open up the lung and keep the lung open
Lachmann, B. (1992) · Intensive Care Medicine · doi:10.1007/bf01694358 · Cited by 1,096
Hh, W., & Tierney, D. F. (1974) · PubMed · doi:10.1164/arrd.1974.110.5.556 · Cited by 941
Yearbook of Intensive Care and Emergency Medicine 2002
(2002) · Springer eBooks · doi:10.1007/978-3-642-56011-8 · Cited by 876
What Has Computed Tomography Taught Us about the Acute Respiratory Distress Syndrome?
GATTINONI, L., CAIRONI, P., PELOSI, P., & GOODMAN, L. R. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.9.2103121 · Cited by 753
Cited by
Costa, E. L. V., Borges, J. B., Melo, A., Suarez-Sipmann, F., Toufen, C., Bohm, S. H., & Amato, M. B. P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1447-y · Cited by 506
Self-citationECMO criteria for influenza A (H1N1)-associated ARDS: role of transpulmonary pressure
Grasso, S., Terragni, P., Birocco, A., Urbino, R., Del Sorbo, L., Filippini, C., Mascia, L., Pesenti, A., Zangrillo, A., Gattinoni, L., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2490-7 · Cited by 227
“Fourth: Several other methods have been proposed to set up an open lung approach [48, 49].”
MethodFutier, E., Constantin, J.-M., Pelosi, P., Chanques, G., Massone, A., Petit, A., Kwiatkowski, F., Bazin, J.-E., & Jaber, S. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31821811ba · Cited by 212
“The possibility of lung overdistension with RM seems unlikely as indicated by a reduction in elastance of the respiratory system in parallel with the increase in EELV, as suggested previously.(39) It has been shown that a pressure of 55 cm H2O during the RM was effective at reopening atelectasis after induction of ane…”
MethodGoligher, E. C., Kavanagh, B. P., Rubenfeld, G. D., Adhikari, N. K. J., Pinto, R., Fan, E., Brochard, L. J., Granton, J. T., Mercat, A., Marie Richard, J.-C., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201404-0688oc · Cited by 194
Chase, J. G., Preiser, J.-C., Dickson, J. L., Pironet, A., Chiew, Y. S., Pretty, C. G., Shaw, G. M., Benyo, B., Moeller, K., Safaei, S., et al. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0455-y · Cited by 189
Electrical impedance tomography
Costa, E. L., Lima, R. G., & Amato, M. B. (2009) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283220e8c · Cited by 189
The Mechanical Ventilator: Past, Present, and Future
Kacmarek, R. M. (2011) · Respiratory Care · doi:10.4187/respcare.01420 · Cited by 165
Nieman, G. F., Satalin, J., Andrews, P., Aiash, H., Habashi, N. M., & Gatto, L. A. (2017) · Intensive Care Medicine Experimental · doi:10.1186/s40635-017-0121-x · Cited by 143
“in a porcine saline lavage-induced ARDS model [93].”
Metadata
- Authors
- Suarez-Sipmann, F., Böhm, S. H., Tusman, G., Pesch, T., Thamm, O., Reissmann, H., Reske, A., Magnusson, A., & Hedenstierna, G.
- Venue
- Critical Care Medicine
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 214-221
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2033128410
- Cited by
- 281
- References
- 30
- FWCI
- 9.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.