Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effect of a nurse-implemented sedation protocol on the incidence of ventilator-associated pneumonia*

Quenot, Jean-Pierre, Ladoire, Sylvain, Devoucoux, Fabrice, Doise, Jean-Marc, Cailliod, Romain, Cunin, Nicole, Aubé, Hervé, Blettery, Bernard, Charles, Pierre Emmanuel·2007·Critical Care Medicine

Abstract

OBJECTIVE: To determine whether the use of a nurse-implemented sedation protocol could reduce the incidence of ventilator-associated pneumonia in critically ill patients. DESIGN: Two-phase (before-after), prospective, controlled study. SETTING: University-affiliated, 11-bed medical intensive care unit. PATIENTS: Patients requiring mechanical ventilation for >or=48 hrs and sedative infusion with midazolam or propofol alone. INTERVENTIONS: During the control phase, sedatives were adjusted according to the physician's decision. During the protocol phase, sedatives were adjusted according to a protocol developed by a multidisciplinary team including nurses and physicians. The protocol was based on the Cambridge scale, and sedation level was adjusted every 3 hrs by the nurses. Standard practices, including weaning from the ventilator and diagnosis of VAP, were the same during both study phases. MEASUREMENTS AND MAIN RESULTS: A total of 423 patients were enrolled (control group, n = 226; protocol group, n = 197). The incidence of VAP was significantly lower in the protocol group compared with the control group (6% and 15%, respectively, p = .005). By univariate analysis (log-rank test), only use of a nurse-implemented protocol was significantly associated with a decrease of incidence of VAP (p < .01). A nurse-implemented protocol was found to be independently associated with a lower incidence of VAP after adjustment on Simplified Acute Physiology Score II in the multivariate Cox proportional hazards model (hazard rate, 0.81; 95% confidence interval, 0.62-0.95; p = .03). The median duration of mechanical ventilation was significantly shorter in the protocol group (4.2 days; interquartile range, 2.1-9.5) compared with the control group (8 days; interquartile range, 2.2-22.0; p = .001), representing a 52% relative reduction. Extubation failure was more frequently observed in the control group compared with the protocol group (13% and 6%, respectively, p = .01). There was no significant difference in in-hospital mortality (38% vs. 45% in the protocol vs. control group, respectively, p = .22). CONCLUSIONS: In patients receiving mechanical ventilation and requiring sedative infusions with midazolam or propofol, the use of a nurse-implemented sedation protocol decreases the rate of VAP and the duration of mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000282733.83089.4d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 217

Metadata

Authors
Quenot, J.-P., Ladoire, S., Devoucoux, F., Doise, J.-M., Cailliod, R., Cunin, N., Aubé, H., Blettery, B., & Charles, P. E.
Venue
Critical Care Medicine
Published
2007-09
Volume
35
Issue
9
Pages
2031-2036
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1985545898
Cited by
217
References
1
FWCI
12.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of a nurse-implemented sedation protocol on the incidence of ventilator-associated pneumonia*. https://app.cochat.ai/papers/10.1097/01.ccm.0000282733.83089.4d
The paper
Quenot, J.-P., Ladoire, S., Devoucoux, F., Doise, J.-M., Cailliod, R., Cunin, N., Aubé, H., Blettery, B., & Charles, P. E. (2007). Effect of a nurse-implemented sedation protocol on the incidence of ventilator-associated pneumonia*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000282733.83089.4d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.