A REANALYSIS OF ATOMIC-BOMB CATARACT DATA, 2000???2002: A THRESHOLD ANALYSIS
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To obtain the best statistical model for a previous study of cataract prevalence in atomic-bomb survivors, we tested the fitness of the threshold model in an updated dataset of the study, utilizing re-diagnosis by a single ophthalmologist, use of the DS02 dosimetry system, and separation of the in utero group. The results suggest that, in 730 atomic-bomb survivors, we cannot conclude thresholds are greater than 0 Sv in cortical cataract and posterior sub-capsular opacity since the lower 90% confidence limits of the thresholds were 0 Sv. Threshold dose point estimates were 0.6 Sv (90% CI, <0.0-1.2 Sv) and 0.7 Sv (90% CI, <0.0-2.8 Sv) for cortical cataract and posterior sub-capsular opacity, respectively. Detailed regression analyses with no threshold model showed that nuclear color and nuclear opacity have no dose responses (p > 0.40). Cortical cataract showed a significant dose effect (p = 0.002), with an odds ratio (OR)/Sv of 1.30 (95% CI, 1.10-1.53) and no dose-effect modifiers. Posterior sub-capsular opacity showed a significant dose effect (p < 0.001), with an OR/Sv of 1.44 at age of exposure of 10 y (95% CI, 1.19-1.73). The dose effect decreased significantly with increasing age at exposure (p = 0.022). No dose response was observed for in utero survivors (p > 0.20).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing proportionality in the proportional odds model for ordinal logistic regression.
Brant, R. (1990) · Biometrics · doi:10.2307/2532457 · Cited by 1,864 · cited 1×
“When slopes are defined in this way using cut-off categories, the slope parameter j generally depends on the cut-off category level j, which is called the partial proportional odds model (Brant 1990; Peterson and Harrell 1990).”
MethodSpace Radiation and Cataracts in Astronauts
Cucinotta, F. A., Manuel, F. K., Jones, J., Iszard, G., Murrey, J., Djojonegro, B., & Wear, M. (2001) · Radiation Research · doi:10.1667/0033-7587(2001)156[0460:sracia]2.0.co;2 · Cited by 391 · cited 2×
“1999), and an astronaut population (Cucinotta et al. 2001), all indicate that threshold dose is not large, which is consistent with our results.”
Result
Cited by
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Chodick, G., Bekiroglu, N., Hauptmann, M., Alexander, B. H., Freedman, D. M., Doody, M. M., Cheung, L. C., Simon, S. L., Weinstock, R. M., Bouville, A., et al. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwn171 · Cited by 407
Radiation Cataractogenesis: A Review of Recent Studies
Ainsbury, E. A., Bouffler, S. D., Dörr, W., Graw, J., Muirhead, C. R., Edwards, A. A., & Cooper, J. (2009) · Radiation Research · doi:10.1667/rr1688.1 · Cited by 374
Cataracts among Chernobyl Clean-up Workers: Implications Regarding Permissible Eye Exposures
Worgul, B. V., Kundiyev, Y. I., Sergiyenko, N. M., Chumak, V. V., Vitte, P. M., Medvedovsky, C., Bakhanova, E. V., Junk, A. K., Kyrychenko, O. Y., Musijachenko, N. V., et al. (2007) · Radiation Research · doi:10.1667/rr0298.1 · Cited by 370
Radiation Cataract Risk in Interventional Cardiology Personnel
Vano, E., Kleiman, N. J., Duran, A., Rehani, M. M., Echeverri, D., & Cabrera, M. (2010) · Radiation Research · doi:10.1667/rr2207.1 · Cited by 360
Metadata
- Authors
- Nakashima, E., Neriishi, K., & Minamoto, A.
- Venue
- Health Physics
- Published
- 2006-02
- Volume
- 90
- Issue
- 2
- Pages
- 154-160
- ISSN
- 0017-9078 (ISSN-L)
- OpenAlex
- W1987286733
- Cited by
- 233
- References
- 2
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.