MANAGEMENT OF SUBMACULAR HEMORRHAGE WITH INTRAVITREAL INJECTION OF TISSUE PLASMINOGEN ACTIVATOR AND EXPANSILE GAS

CHEN, CHRISTINE Y., HOOPER, CLAIRE, CHIU, DANIEL, CHAMBERLAIN, MATTHEW, KARIA, NIRAL, HERIOT, WILSON J. · 2007 · Retina
Cited by 124

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In Brief Purpose: To evaluate the clinical outcome of intravitreal tissue plasminogen activator (tPA) and expansile gas injection as a minimally invasive treatment for submacular hemorrhage (SMH). Methods: This study was a retrospective clinical case series examining 104 eyes that received an intravitreal injection of 30–100 mcg of tPA and expansile gas (SF6 or C3F8) for SMH. The main outcomes evaluated were visual acuities (VA), anatomic displacement of submacular blood, and surgical complications. Results: A total of 85, 77, and 81 eyes were available at 1 week, 3 months, and 12 months follow up, respectively. Postoperatively, ≥2 Snellen lines improvement were achieved in 43/85 eyes (51%) at 1 week, 49/77 eyes (63%) at 3 months, and 52/81 eyes (64%) at 12 months. Postoperative VA improvement was significantly associated with preoperative VA, submacular blood displacement, and the underlying cause of SMH. Diagnostic postoperative angiogram and clinical examination were possible at 8.2 ± 7.4 weeks and 9.5 ± 7.4 weeks, respectively. The observed complications included breakthrough vitreous hemorrhage in 8 eyes (8%) and retinal detachment in 3 eyes (3%). Conclusions: In this retrospective series, intravitreal injection of tPA and expansile gas was shown to be a safe and effective technique that can improve VA in most eyes with SMH and assist in the diagnosis of the underlying cause. This retrospective clinical series examined 104 eyes to evaluate the clinical outcome of intravitreal injection of tissue plasminogen activator and expansile gas as a minimally invasive treatment for submacular hemorrhage. This treatment can improve visual acuity and accelerate diagnosis of the underlying cause with minimal complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.iae.0000237586.48231.75

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 124

Metadata

Authors
CHEN, C. Y., HOOPER, C., CHIU, D., CHAMBERLAIN, M., KARIA, N., & HERIOT, W. J.
Venue
Retina
Published
2007-03
Volume
27
Issue
3
Pages
321-328
ISSN
0275-004X (ISSN-L)
OpenAlex
W1987813682
Cited by
124
References
2
FWCI
3.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MANAGEMENT OF SUBMACULAR HEMORRHAGE WITH INTRAVITREAL INJECTION OF TISSUE PLASMINOGEN ACTIVATOR AND EXPANSILE GAS. https://app.cochat.ai/papers/10.1097/01.iae.0000237586.48231.75
The paper
CHEN, C. Y., HOOPER, C., CHIU, D., CHAMBERLAIN, M., KARIA, N., & HERIOT, W. J. (2007). MANAGEMENT OF SUBMACULAR HEMORRHAGE WITH INTRAVITREAL INJECTION OF TISSUE PLASMINOGEN ACTIVATOR AND EXPANSILE GAS. Retina. https://doi.org/10.1097/01.iae.0000237586.48231.75

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.