Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

The Aqueous Outflow System as a Mechanical Pump: Evidence from Examination of Tissue and Aqueous Movement in Human and Non-Human Primates

Johnstone, Murray A · 2004 · Journal of Glaucoma

Abstract

PURPOSE: To describe a new aqueous outflow model involving a mechanical pump. MATERIALS AND METHODS: Laboratory materials include human and monkey eyes; methods include the dissecting microscope, light microscopy, scanning electron microscopy, transmission electron microscopy, and tracer studies. Clinical methods involve human subject slit lamp, gonioscopy, and operating microscope examination. RESULTS: Laboratory evidence demonstrates that aqueous outflow tissues are responsive to intraocular pressure induced deformation. Deformation occurs in response to small pressure gradients. Laboratory evidence also demonstrates the presence of valves discharging aqueous to Schlemm's canal. The laboratory model predicts pulsatile aqueous discharge in vivo. Clinical in vivo evidence demonstrates pulsatile aqueous flow from the anterior chamber into Schlemm's canal, from Schlemm's canal into collector channels, and from Schlemm's canal into aqueous and episcleral veins, all synchronous with the ocular pulse. CONCLUSIONS: Aqueous outflow tissue deformation caused by normal intraocular pressure transients induces pulsatile one-way discharge of aqueous to the vascular system. The model identifies biomechanical coupling of intraocular pressure with aqueous outflow tissue deformation and also sites of high flow capable of inducing shear stress. These mechanotransduction mechanisms, well characterized as a means of controlling pressure and flow in the vascular system, also provide a means of regulatory feedback to control intraocular pressure and aqueous flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ijg.0000131757.63542.24

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Johnstone, M. A.
Venue
Journal of Glaucoma
Published
2004-10
Volume
13
Issue
5
Pages
421-438
ISSN
1057-0829 (ISSN-L)
OpenAlex
W2083909858
Cited by
183
References
0
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Aqueous Outflow System as a Mechanical Pump: Evidence from Examination of Tissue and Aqueous Movement in Human and Non-Human Primates. https://app.cochat.ai/papers/10.1097/01.ijg.0000131757.63542.24
The paper
Johnstone, M. A. (2004). The Aqueous Outflow System as a Mechanical Pump: Evidence from Examination of Tissue and Aqueous Movement in Human and Non-Human Primates. Journal of Glaucoma. https://doi.org/10.1097/01.ijg.0000131757.63542.24

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.