Diagnosis of Catheter-Related Bloodstream Infections Among Pediatric Oncology Patients Lacking a Peripheral Culture, Using Differential Time to Detection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Current methods for in situ diagnosis of catheter-related bloodstream infections require concurrent collection of central venous catheter (CVC) and peripheral vein (PV) blood cultures. Both the pain and inconvenience of PV cultures are undesirable. METHODS: A prospective study was conducted (August 2002 to March 2004) to assess the accuracy of diagnosing catheter-related bloodstream infections based on the difference in time to detection of blood cultures drawn concurrently from 2 lumens of a multilumen CVC. This difference in time to detection between 2 lumens was compared with results of the standard criterion with paired CVC and PV blood cultures. RESULTS: Twenty-one infectious episodes were categorized as catheter-related bloodstream infections and 38 as non-catheter-related bloodstream infections. With a cutoff in difference in time to detection between 2 lumens of > or =180 minutes, the sensitivity of this test to diagnose a catheter-related bloodstream infection was 61% (95% confidence interval, 39-80%) and the specificity was 94% (95% confidence interval, 82-99%). In 4 of 7 episodes with false-negative results, the colony counts in cultures from both lumens were >400 colony-forming units/mL (maximal value reported), indicating the limitation of this method when both lumens of the catheter are colonized. With the pretest probability of catheter-related bloodstream infections ranging from 28% to 54%, the positive predictive value of a difference in time to detection between 2 lumens of > or =180 minutes for diagnosis of catheter-related bloodstream infections ranged from 81% to 93% and the negative predictive value ranged from 67% to 86%. CONCLUSION: Within the context of its limitations, this novel method provides an alternative for diagnosing catheter-related bloodstream infections among patients with a CVC, without PV cultures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Cited by
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“Predictors of CRBSI involving long-term catheters include the following: a 13:1 quantity of Candida growing from the catheter-drawn blood cultures, compared with percutaneous blood cultures; catheterdrawn blood cultures growing 12 h before percutaneous blood cultures [36, 48, 49, 198]; candidemia in a patient who has…”
BackgroundInfluentialSelf-citationFreifeld, A. G., Bow, E. J., Sepkowitz, K. A., Boeckh, M. J., Ito, J. I., Mullen, C. A., Raad, I. I., Rolston, K. V., Young, J.-A. H., & Wingard, J. R. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir073 · Cited by 3,463
Updated Review of Blood Culture Contamination
Hall, K. K., & Lyman, J. A. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.00062-05 · Cited by 875
Freifeld, A. G., Bow, E. J., Sepkowitz, K. A., Boeckh, M. J., Ito, J. I., Mullen, C. A., Raad, I. I., Rolston, K. V., Young, J.-A. H., & Wingard, J. R. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/ciq147 · Cited by 704
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Metadata
- Authors
- Gaur, A. H., Flynn, P. M., Heine, D. J., Giannini, M. A., Shenep, J. L., & Hayden, R. T.
- Venue
- Pediatric Infectious Disease Journal
- Published
- 2005-05
- Volume
- 24
- Issue
- 5
- Pages
- 445-449
- ISSN
- 0891-3668 (ISSN-L)
- OpenAlex
- W1999005097
- Cited by
- 64
- References
- 1
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.