Preliminary Experience Using High Intensity Focused Ultrasound for the Treatment of Patients With Advanced Stage Renal Malignancy
Abstract
PURPOSE: We present the preliminary results of patients with advanced stage renal malignancy treated with high intensity focused ultrasound (HIFU), and investigate the safety and feasibility of using HIFU in the treatment of selected patients with renal tumors. MATERIALS AND METHODS: HIFU treatment was performed in 12 patients with advanced stage renal cell carcinoma and 1 patient with colon cancer metastasized to kidney. Patients were followed after treatment to observe complications and long-term therapeutic efficacy. Complications and changes in symptoms seen at presentation were recorded. Mid stream urine specimens were sent for microscopy and serum creatinine was measured postoperatively. Followup radiological examinations were performed to detect tumor response to the ablation. RESULTS: A total of 13 patients received HIFU treatment safely, including 10 who had partial ablation and 3 who had complete tumor ablation. After HIFU hematuria disappeared in 7 of 8 patients and flank pain of presumed malignant origin disappeared in 9 of 10 patients. Postoperative images showed decrease in or absence of tumor blood supply in the treated region and significant shrinkage of the ablated tumor. Of the 13 patients 7 died (median survival 14.1 months, range 2 to 27) and 6 were still alive with median followup of 18.5 months (range 10 to 27). CONCLUSIONS: This preliminary experience suggests that HIFU could be safe and feasible in the treatment of patients with advanced renal malignancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guideline for Management of the Clinical T1 Renal Mass
Campbell, S. C., Novick, A. C., Belldegrun, A., Blute, M. L., Chow, G. K., Derweesh, I. H., Faraday, M. M., Kaouk, J. H., Leveillee, R. J., Matin, S. F., et al. (2009) · Journal of Urology · doi:10.1016/j.juro.2009.07.004 · Cited by 1,831
High-intensity focused ultrasound in the treatment of solid tumours
Kennedy, J. E. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1591 · Cited by 1,282
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
High intensity focused ultrasound in clinical tumor ablation
Zhou, Y.-F. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i1.8 · Cited by 625
Izadifar, Z., Izadifar, Z., Chapman, D., & Babyn, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020460 · Cited by 457
Metadata
- Authors
- WU, F., WANG, Z.-B., CHEN, W.-Z., BAI, J., ZHU, H., & QIAO, T.-Y.
- Venue
- Journal of Urology
- Published
- 2003-12
- Volume
- 170
- Issue
- 6
- Pages
- 2237-2240
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2016173997
- Cited by
- 211
- References
- 0
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preliminary Experience Using High Intensity Focused Ultrasound for the Treatment of Patients With Advanced Stage Renal Malignancy. https://app.cochat.ai/papers/10.1097/01.ju.0000097123.34790.70
- The paper
- WU, F., WANG, Z.-B., CHEN, W.-Z., BAI, J., ZHU, H., & QIAO, T.-Y. (2003). Preliminary Experience Using High Intensity Focused Ultrasound for the Treatment of Patients With Advanced Stage Renal Malignancy. Journal of Urology. https://doi.org/10.1097/01.ju.0000097123.34790.70
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.