The DOI matches its Crossref record.
Bone-Anchored Hearing Aids in Unilateral Inner Ear Deafness: An Evaluation of Audiometric and Patient Outcome Measurements
Open accessAbstract
OBJECTIVE: To evaluate the benefit of a bone-anchored hearing aid contralateral routing of sound hearing aid (BAHA CROS hearing aid) in 29 patients with unilateral inner ear deafness. STUDY DESIGN: Prospective clinical follow-up study. SETTING: Tertiary referral center. PATIENTS: Thirty patients were recruited. There were 19 patients with a history of acoustic neuroma surgery and 11 patients with unilateral inner ear deafness due to other causes; 1 patient was excluded. The first 21 patients had also participated in a previous evaluation. INTERVENTION: Audiometric measurements were taken before intervention, when fitted with a conventional CROS, and after BAHA implementation. Patients' subjective benefit was quantified with four different hearing aid-specific instruments: the Abbreviated Profile of Hearing Aid Benefit, the Glasgow Hearing Aid Benefit Profile, the International Outcome Inventory for Hearing Aids, and the Single-Sided Deafness questionnaire. MAIN OUTCOME MEASURES: The same instruments were used at a mean long-term follow-up of 1 year after BAHA implantation. RESULTS: Sound localization in an audiologic test setting was no different from chance level. The main effect of the BAHA CROS that was found was the "lift the head shadow" effect in the speech-in-noise measurements. All instruments also showed positive results in favor of the BAHA CROS at long-term follow-up. CONCLUSIONS: The poor sound-localization results in an audiologic test setting illustrated the inability of patients with unilateral inner ear deafness to localize sounds. The speech-in-noise measurements demonstrated the efficacy of the BAHA CROS to lift the head shadow. Patients were still satisfied at 1-year follow-up, according to the four instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Practice Guideline: Sudden Hearing Loss
Stachler, R. J., Chandrasekhar, S. S., Archer, S. M., Rosenfeld, R. M., Schwartz, S. R., Barrs, D. M., Brown, S. R., Fife, T. D., Ford, P., Ganiats, T. G., et al. (2012) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599812436449 · Cited by 971
Clinical Practice Guideline: Sudden Hearing Loss (Update)
Chandrasekhar, S. S., Tsai Do, B. S., Schwartz, S. R., Bontempo, L. J., Faucett, E. A., Finestone, S. A., Hollingsworth, D. B., Kelley, D. M., Kmucha, S. T., Moonis, G., et al. (2019) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599819859885 · Cited by 931
Consensus Statements on the BAHA System: Where Do We Stand at Present?
Snik, F. M., Mylanus, E. A. M., Proops, D. W., Wolfaardt, J. F., Hodgetts, W. E., Somers, T., Niparko, J. K., Wazen, J. J., Sterkers, O., Cremers, W. R. J., et al. (2005) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/0003489405114s1201 · Cited by 277
Self-citation
Metadata
- Authors
- Hol, M. K. S., Bosman, A. J., Snik, A. F. M., Mylanus, E. A. M., & Cremers, C. W. R. J.
- Venue
- Otology & Neurotology
- Published
- 2005-09
- Volume
- 26
- Issue
- 5
- Pages
- 999-1006
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W2128554992
- Cited by
- 170
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bone-Anchored Hearing Aids in Unilateral Inner Ear Deafness: An Evaluation of Audiometric and Patient Outcome Measurements. https://app.cochat.ai/papers/10.1097/01.mao.0000185065.04834.95
- The paper
- Hol, M. K. S., Bosman, A. J., Snik, A. F. M., Mylanus, E. A. M., & Cremers, C. W. R. J. (2005). Bone-Anchored Hearing Aids in Unilateral Inner Ear Deafness: An Evaluation of Audiometric and Patient Outcome Measurements. Otology & Neurotology. https://doi.org/10.1097/01.mao.0000185065.04834.95
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.