The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Transoral Robotic Surgery: Supraglottic Laryngectomy in a Canine Model
Abstract
OBJECTIVES/HYPOTHESIS: To develop a technique for computer enhanced robotic transoral supraglottic partial laryngectomy in the canine model. STUDY DESIGN: Surgical procedure on the larynx in a canine model with a commercially available surgical robot. METHODS: With use of the da Vinci Surgical Robot (Intuitive Surgical, Inc., Sunnyvale, CA), the supraglottic partial laryngectomy was performed on a mongrel dog that had been orotracheally intubated using general anesthesia. The videoscope and the 8 mm end-effectors of the robotic system were introduced through three ports, transorally. The surgical procedure was performed remotely from the robotic system console. The procedure was documented with still and video photography. RESULTS: Supraglottic partial laryngectomy was successfully performed using the da Vinci Surgical Robot, with 8 mm instrumentation. The robotic system allowed for celerity and accuracy secondary to findings specific to the surgical approach, including excellent hemostasis, superb visualization of the operative field with expeditious identification of laryngeal submucosal soft tissue and skeletal landmarks, and multiplanar transection of tissues. In addition, the use of the robotic system also was found to have technical advantages inherent in robotic surgery, including the use of "wristed" instrumentation, tremor abolition, motion scaling, and three-dimensional vision. CONCLUSIONS: The da Vinci Surgical Robot allowed for successful robotic transoral supraglottic partial laryngectomy in the canine model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robotic surgery in urology: fact or fantasy?
Binder, J., Bräutigam, R., Jonas, D., & Bentas, W. (2004) · British Journal of Urology · doi:10.1046/j.1464-410x.2004.05130.x · Cited by 105
Cited by
Transoral Robotic Surgery (TORS) for Base of Tongue Neoplasms
O'Malley, B. W., Weinstein, G. S., Snyder, W., & Hockstein, N. G. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227184.90514.1a · Cited by 740
Self-citationA consensus document on robotic surgery
The SAGES-MIRA Robotic Surgery Consensus Group, Herron, D. M., & Marohn, M. (2008) · Surgical Endoscopy · doi:10.1007/s00464-007-9727-5 · Cited by 421
Da Vinci Xi robot-assisted penetrating keratoplasty
Chammas, J., Sauer, A., Pizzuto, J., Pouthier, F., Gaucher, D., Marescaux, J., Mutter, D., & Bourcier, T. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.3.21 · Cited by 52
Metadata
- Authors
- Weinstein, G. S., O???Malley, B. W., & Hockstein, N. G.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2005-07
- Volume
- 115
- Issue
- 7
- Pages
- 1315-1319
- ISSN
- 0023-852X (ISSN-L)
- OpenAlex
- W2101587433
- Cited by
- 281
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transoral Robotic Surgery: Supraglottic Laryngectomy in a Canine Model. https://app.cochat.ai/papers/10.1097/01.mlg.0000170848.76045.47
- The paper
- Weinstein, G. S., O???Malley, B. W., & Hockstein, N. G. (2005). Transoral Robotic Surgery: Supraglottic Laryngectomy in a Canine Model. The Laryngoscope. https://doi.org/10.1097/01.mlg.0000170848.76045.47
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.