Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

Continuous Laryngoscopy Exercise Test: A Method for Visualizing Laryngeal Dysfunction during Exercise

Open access
Heimdal, John‐Helge, Roksund, Ola D., Halvorsen, Thomas, Skadberg, Britt T., Olofsson, Jan·2006·The Laryngoscope

Abstract

Objectives/Hypothesis: To assess the diagnostic feasibility and patient acceptance of a new developed diagnostic test for exercise induced upper airway flow limitation. Study Design: Clinical case control study including evaluation of contemporary ergo‐spirometry and laryngoscopy continuously performed during exercise. Methods: Twelve nonsymptomatic controls and four young females with documented dyspnea and noisy breathing during exercise were studied. All subjects exercised to exhaustion on a treadmill while attached to a fully equipped ergo‐spirometry unit and a fiberoptic laryngoscope linked to a video camera and a sound recorder. Results: The test situation was well tolerated. Two control subjects had a minor inspiratory synchronous medial motion of the aryepiglottic folds without limitation of laryngeal airflow. In the four symptomatic subjects, exercise induced inspiratory synchronous medial motion of the dorsal part of the aryepiglottic folds as well as vocal cord adduction and inspiratory stridor was demonstrated. Conclusion: The continuous laryngoscopy exercise test was easy to perform, well tolerated, and can be implemented in future diagnostic work‐up programs of laryngeal dysfunction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mlg.0000184528.16229.ba

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Heimdal, J., Roksund, O. D., Halvorsen, T., Skadberg, B. T., & Olofsson, J.
Venue
The Laryngoscope
Publisher
Wiley
Published
2006-01
Volume
116
Issue
1
Pages
52-57
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2011410336
Cited by
230
References
0
FWCI
5.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Laryngoscopy Exercise Test: A Method for Visualizing Laryngeal Dysfunction during Exercise. https://app.cochat.ai/papers/10.1097/01.mlg.0000184528.16229.ba
The paper
Heimdal, J., Roksund, O. D., Halvorsen, T., Skadberg, B. T., & Olofsson, J. (2006). Continuous Laryngoscopy Exercise Test: A Method for Visualizing Laryngeal Dysfunction during Exercise. The Laryngoscope. https://doi.org/10.1097/01.mlg.0000184528.16229.ba

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.