Evaluation of a Navigation System for ENT with Surgical Efficiency Criteria
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The aim of this study is the evaluation of a navigation system (NaviBase) for ENT surgery. For this purpose, a new methodology for the evaluation of surgical and ergonomic system properties has been developed. The practicability of the evaluation instruments will be examined using the example of the overall assessment of the system in comparison with the current surgical standard and with other systems using clinical efficiency criteria. The evaluation is based on 102 ENT surgical applications; of these, 89 were functional endoscopic sinus surgeries (FESS). The evaluation of surgical and ergonomic performance factors was performed by seven ENT surgeons. To evaluate surgical system properties, the Level of Quality (LOQ) in 89 cases of the FESS was determined. It compares the existing information of the surgeon with that of the navigation system on a scale of 0 to 100 and with a mean value of 50 and places it in a relationship to the clinical impact. The intraoperative change of the planned surgical strategy (Change of Surgical Strategy) was documented. The ergonomic factors of the system with the categories of Overall Confidence (Trust), awareness of the situation (Situation Awareness), influence on the operating team, requirements for specific skills (Skill Set Requirement), and cognitive load (Workload Shift) were recorded for all surgical procedures as Level of Reliance (LOR). In the evaluation of the surgical system properties, an average evaluation of the quality of the information, as an LOQ of 63.59, resulted. Every second application of the navigation system (47.9%), on average, led to a change in the surgical strategy. An extension/enhancement of the indication of the endonasal approach through the use of the navigation system was shown in 7 of 102 (6.8%) cases. The completion of the resection in the FESS was rated by 74% of group I and 11% of group II as better in comparison with the standard approach. Total confidence shows a positive evaluation of 3.35 in the LOR. To supplement the evaluation of the navigation system, the technical parameters were included. The maximum deviation, Amax, of the displayed position of the reference value amounted to 1.93 mm. The average deviation was at 1.29 mm with an SD above all values, sd, of 0.29. The subsequent economic evaluation resulted in an effective average extra expenditure of time of 1.35 minutes per case. The overall evaluation of the system imparts application-relevant information beyond the technical details and permits comparability between different assistance systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trust in Automation: Designing for Appropriate Reliance
Lee, J. D., & See, K. A. (2004) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/hfes.46.1.50_30392 · Cited by 6,605
A model for types and levels of human interaction with automation
Parasuraman, R., Sheridan, T. B., & Wickens, C. D. (2000) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.844354 · Cited by 4,195
The role of trust in automation reliance
Dzindolet, M. T., Peterson, S. A., Pomranky, R. A., Pierce, L. G., & Beck, H. P. (2003) · International Journal of Human-Computer Studies · doi:10.1016/s1071-5819(03)00038-7 · Cited by 1,276 · cited 2×
“In the remaining operations (biopsies, tumor operations), there were higher conversion rates after application of the navigation than was the case with FESS.(4) An expansion of the indication of the endonasal approach through the use of the navigation system was indicated in 7 of 102 (6.”
Influential
Cited by
International consensus statement on allergy and rhinology: rhinosinusitis 2021
Orlandi, R. R., Kingdom, T. T., Smith, T. L., Bleier, B., DeConde, A., Luong, A. U., Poetker, D. M., Soler, Z., Welch, K. C., Wise, S. K., et al. (2021) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22741 · Cited by 959
International Consensus Statement on Allergy and Rhinology: Rhinosinusitis
Orlandi, R. R., Kingdom, T. T., Hwang, P. H., Smith, T. L., Alt, J. A., Baroody, F. M., Batra, P. S., Bernal‐Sprekelsen, M., Bhattacharyya, N., Chandra, R. K., et al. (2016) · International Forum of Allergy & Rhinology · doi:10.1002/alr.21695 · Cited by 892
Schaefer, K. E., Chen, J. Y. C., Szalma, J. L., & Hancock, P. A. (2016) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720816634228 · Cited by 768
Systematic review of measurement tools to assess surgeons' intraoperative cognitive workload
Dias, R. D., Ngo-Howard, M. C., Boskovski, M. T., Zenati, M. A., & Yule, S. J. (2018) · British Journal of Surgery · doi:10.1002/bjs.10795 · Cited by 273
Metadata
- Authors
- Strau, G., Koulechov, K., R??ttger, S., Bahner, J., Trantakis, C., Hofer, M., Korb, W., Burgert, O., Meixensberger, J., Manzey, D., Dietz, A., & L??th, T.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2006-04
- Volume
- 116
- Issue
- 4
- Pages
- 564-572
- ISSN
- 0023-852X (ISSN-L)
- OpenAlex
- W2057650652
- Cited by
- 66
- References
- 3
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a Navigation System for ENT with Surgical Efficiency Criteria. https://app.cochat.ai/papers/10.1097/01.mlg.0000202091.34295.05
- The paper
- Strau, G., Koulechov, K., R??ttger, S., Bahner, J., Trantakis, C., Hofer, M., Korb, W., Burgert, O., Meixensberger, J., Manzey, D., Dietz, A., & L??th, T. (2006). Evaluation of a Navigation System for ENT with Surgical Efficiency Criteria. The Laryngoscope. https://doi.org/10.1097/01.mlg.0000202091.34295.05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.