The DOI matches its Crossref record.
Multichannel Cochlear Implants: Relation of Histopathology to Performance
Abstract
Objectives: To determine the relationship of surviving neural elements to auditory function in multichannel cochlear implant temporal bones. Study Design: Case series of all 14 existing multichannel cochlear implants in our temporal bone collection. Methods: Devices included Nucleus 22 (n = 11), Nucleus 24 (n = 1), Ineraid (n = 1), and Clarion (n = 1). Morphologic evaluation of structural elements including spiral ligament, stria vascularis, hair cells, peripheral processes, and spiral ganglion cells was performed. Clinical performance data were obtained from patient charts. For eight patients, nonimplanted contralateral temporal bones were available and paired comparisons were made. Results: Despite frequent absence of hair cells and peripheral processes, all bones had at least some remaining spiral ganglion cells. Percent of normal remaining structures were unrelated to auditory performance with the implant for any of the structural elements. Ganglion cell count in segment III showed significant negative correlations to speech discrimination scores for words and sentences (Rhos = −.687 and −.661, P ≤ .03 and .04) as did segment IV and total ganglion cell count with word score (Rhos = −.632 and −.638; P ≤ .05). Spiral ganglion cell survival did not differ between implanted and nonimplanted ears, with the exception of segment I, which had fewer cells in the implanted ear (P ≤ .028). Conclusions: Performance variability of cochlear implants cannot be explained on the basis of cochlear neuronal survival. Although hair cells and peripheral processes were frequently absent or greatly diminished from normal, all subjects had at least some spiral ganglion cells. And, in this series, there was an inverse relationship between survival of ganglion cells and performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Polypyrrole-coated electrodes for the delivery of charge and neurotrophins to cochlear neurons
Richardson, R. T., Wise, A. K., Thompson, B. C., Flynn, B. O., Atkinson, P. J., Fretwell, N. J., Fallon, J. B., Wallace, G. G., Shepherd, R. K., Clark, G. M., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.015 · Cited by 304
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
Metadata
- Authors
- Fayad, J. N., & Linthicum, F. H.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2006-08
- Volume
- 116
- Issue
- 8
- Pages
- 1310-1320
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2029973746
- Cited by
- 222
- References
- 0
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multichannel Cochlear Implants: Relation of Histopathology to Performance. https://app.cochat.ai/papers/10.1097/01.mlg.0000227176.09500.28
- The paper
- Fayad, J. N., & Linthicum, F. H. (2006). Multichannel Cochlear Implants: Relation of Histopathology to Performance. The Laryngoscope. https://doi.org/10.1097/01.mlg.0000227176.09500.28
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.