Pediatric Intravenous Insertion in the Emergency Department: Bevel Up or Bevel Down?
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Intravenous catheters are usually inserted with the bevel facing up. Bevel down may be superior in small and/or dehydrated children. We seek to determine whether there is a difference in the success rate of intravenous insertion using these 2 methods. METHODS: We recruited children requiring an intravenous catheter in the emergency department where there was time to obtain consent. Patients were randomized to have the first attempt bevel up or bevel down. If the first attempt was unsuccessful, the alternate technique was used on second attempt. Attempts beyond 2 were not tracked. RESULTS: We recruited 428 patients. Data are available from 396 (201 bevel-up and 195 bevel-down techniques). At least 63 different nurses participated. The nurses participated in the study a median number of 2 times (maximum, 36). Four nurses used the bevel-down technique more than 10 times. The success rate on first attempt was 75.6% (95% confidence interval [CI], 69.8-81.4) for bevel up and 60% (95% CI, 53.2-66.8) for bevel down. The success rate on second attempt was 56.8% (95% CI, 45.3-68.2) for bevel up and 42.9% (95% CI, 30.3-55.5) for bevel down. In the subgroup of infants weighing less than 5 kg, there was no difference between the 2 techniques on the first attempt, with bevel up having a success of 33% (95% CI, 8.4-57.6) and bevel down 30% (95% CI, 4.1-55.9). CONCLUSIONS: The bevel-up technique performed superior to bevel-down technique in this study. The bevel-down technique might be useful in small infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Failed attempts and improvement strategies in peripheral intravenous catheterization
Sabri, A., Szalas, J., Holmes, K. S., Labib, L., & Mussivand, T. (2013) · Bio-Medical Materials and Engineering · doi:10.3233/bme-120735 · Cited by 146
“…– ED [11] 214 (children) FASR: 74% – Hospital [12] 592 (0–18 y) FASR: 46%; MNA: 2.1 overall mean: 28 min Presurgical [13] Infants to adolescents ED [14] 396 (0–18 y) FASR: overall: non-randomized: 68%; B ↑ : 76%; B ↓ : 60% – <5 kg: non-randomized: 33%; B ↑ : 33%; B ↓ : 30% (NS) ∗ tourniquet has…”
InfluentialPeripheral Difficult Venous Access in Children
Rauch, D., Dowd, D., Eldridge, D., Mace, S., Schears, G., & Yen, K. (2009) · Clinical Pediatrics · doi:10.1177/0009922809335737 · Cited by 80
Difficult peripheral venous access: recognizing and managing the patient at risk
Walsh, G. (2008) · Journal of the Association for Vascular Access · doi:10.2309/java.13-4-7 · Cited by 58
Metadata
- Authors
- Black, K. J. L., Pusic, M. V., Harmidy, D., & McGillivray, D.
- Venue
- Pediatric Emergency Care
- Published
- 2005-11
- Volume
- 21
- Issue
- 11
- Pages
- 707-711
- ISSN
- 0749-5161 (ISSN-L)
- OpenAlex
- W1965000335
- Cited by
- 51
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pediatric Intravenous Insertion in the Emergency Department: Bevel Up or Bevel Down? https://app.cochat.ai/papers/10.1097/01.pec.0000186422.77140.1f
- The paper
- Black, K. J. L., Pusic, M. V., Harmidy, D., & McGillivray, D. (2005). Pediatric Intravenous Insertion in the Emergency Department: Bevel Up or Bevel Down? Pediatric Emergency Care. https://doi.org/10.1097/01.pec.0000186422.77140.1f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.