Urine Specific Gravity and Other Urinary Indices: Inaccurate Tests for Dehydration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Urine output, specific gravity, and ketones (urinary indices) are commonly used as an objective means to assess for dehydration and gastroenteritis severity; however, their utility has not been established. The study was designed to evaluate the accuracy of urinary indices as diagnostic tests to identify acute dehydration. METHODS: We completed a prospective cohort study in the Emergency Department of an urban pediatric hospital. Seventy-nine subjects ages 3 months to 36 months with gastroenteritis, clinically suspected moderate dehydration, and the need for intravenous rehydration were enrolled in the trial. Urine specific gravity and urine ketone levels were determined with bedside calorimetric (dipstick) testing, and urine output during rehydration and observation was measured by commonly used techniques. An internally validated, weight-based criterion standard for the percent dehydration on enrollment was used to identify the cohort of dehydrated subjects. Correlation statistics were calculated for urine output, specific gravity, and ketones. In addition, multilevel tables were created to determine the sensitivity, specificity, and likelihood ratio at varying test cutoff values to detect 3% and 5% dehydration. RESULTS: Urine specific gravity (r = -0.06, P = 0.64), urine ketones (r = 0.08, P = 0.52), and urine output during rehydration (r = 0.01, P = 0.96) did not correlate with the initial degree of dehydration present. Clinically useful cutoff values for urine specific gravity and ketones to increase or decrease the likelihood of dehydration at the time of enrollment could not be identified. CONCLUSIONS: Urinary indices are not useful diagnostic tests to identify the presence of dehydration during the initial assessment of children with gastroenteritis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Likelihood ratios with confidence: Sample size estimation for diagnostic test studies
Simel, D. L., Samsa, G. P., & Matchar, D. B. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90128-v · Cited by 932 · cited 2×
“Confidence intervals for the LRs were calculated in the method recommended by Simel et al.(31)”
Method
Cited by
Dehydration: Physiology, Assessment, and Performance Effects
Cheuvront, S. N., & Kenefick, R. W. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130017 · Cited by 461
“A postmorbid body weight that is 2% less than documented “well weights” might similarly be used in the absence of a valid premorbid measurement (343).”
Fortes, M. B., Owen, J. A., Raymond-Barker, P., Bishop, C., Elghenzai, S., Oliver, S. J., & Walsh, N. P. (2015) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2014.09.012 · Cited by 158
Physiologic basis for understanding quantitative dehydration assessment
Cheuvront, S. N., Kenefick, R. W., Charkoudian, N., & Sawka, M. N. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.112.044172 · Cited by 154
Metadata
- Authors
- Steiner, M. J., Nager, A. L., & Wang, V. J.
- Venue
- Pediatric Emergency Care
- Published
- 2007-05
- Volume
- 23
- Issue
- 5
- Pages
- 298-303
- ISSN
- 0749-5161 (ISSN-L)
- OpenAlex
- W1983791426
- Cited by
- 45
- References
- 1
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Urine Specific Gravity and Other Urinary Indices: Inaccurate Tests for Dehydration. https://app.cochat.ai/papers/10.1097/01.pec.0000270162.76453.fa
- The paper
- Steiner, M. J., Nager, A. L., & Wang, V. J. (2007). Urine Specific Gravity and Other Urinary Indices: Inaccurate Tests for Dehydration. Pediatric Emergency Care. https://doi.org/10.1097/01.pec.0000270162.76453.fa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.