CoChat

Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers

Hijjawi, John B., Kuiken, Todd A., Lipschutz, Robert D., Miller, Laura A., Stubblefield, Kathy A., Dumanian, Gregory A. · 2006 · Plastic and Reconstructive Surgery
Cited by 157

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The control of shoulder-level disarticulation prostheses is significantly more difficult than that of prostheses for more distal amputations. Amputees have significant difficulties coordinating the separate functions of prosthetic shoulder, elbow, wrist, and hand/hook components. The user must lock one joint at a particular position in space before subsequently moving a different joint. METHODS: A patient with bilateral humeral disarticulations after an electrical injury underwent a novel nerve transfer procedure designed to improve the control of a myoelectric prosthesis. The median, radial, ulnar, and musculocutaneous nerves were transferred to the nerves of segments of the pectoralis major and minor muscles. Those muscles then act as bioamplifiers of peripheral nerve signals when the normal upper extremity nerves are activated by the patient's brain. Therefore, when the patient thinks "flex elbow," the transferred musculocutaneous nerve fires, and a segment of the pectoralis major contracts. An electromyographic signal is then detected transcutaneously and causes the prosthetic elbow to flex. RESULTS: Three of the four nerve transfers were successful. One of the nerve transfers unexpectedly yielded two separate controllable muscle segments. Standardized testing using a "box-and-blocks" apparatus was performed with the patient's previous myoelectric device and the current device after nerve transfers. The patient's performance improved by 246 percent. CONCLUSIONS: Nerve transfers to small muscle segments are capable of creating a novel neural interface for improved control of a myoelectric prosthesis. This is done using standard techniques of nerve and flap surgery, and without any implantable devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.prs.0000242487.62487.fb

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 157

Metadata

Authors
Hijjawi, J. B., Kuiken, T. A., Lipschutz, R. D., Miller, L. A., Stubblefield, K. A., & Dumanian, G. A.
Venue
Plastic and Reconstructive Surgery
Published
2006-12
Volume
118
Issue
7
Pages
1573-1578
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2010573798
Cited by
157
References
1
FWCI
5.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers. https://app.cochat.ai/papers/10.1097/01.prs.0000242487.62487.fb
The paper
Hijjawi, J. B., Kuiken, T. A., Lipschutz, R. D., Miller, L. A., Stubblefield, K. A., & Dumanian, G. A. (2006). Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers. Plastic and Reconstructive Surgery. https://doi.org/10.1097/01.prs.0000242487.62487.fb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.