CoChat

Development and Validation of a Novel Scar Evaluation Scale

Singer, Adam J., Arora, Blavantray, Dagum, Alexander, Valentine, Sharon, Hollander, Judd E. · 2007 · Plastic and Reconstructive Surgery
Cited by 238

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The authors previously developed a six-item ordinal wound evaluation scale to measure the short-term cosmetic outcome of wounds 1 week after injury. Although it was never intended to measure long-term outcomes, it has been used to assess scars 3 to 12 months after injury. The authors developed and validated a scar evaluation scale specifically aimed at measuring the long-term appearance of scars. METHODS: Two plastic surgeons and one emergency physician, blinded to each other's assessments, viewed photographs of 50 scars resulting from lacerations or surgical incisions. Scars were assigned 0 or 1 point each for the presence or absence of the following: width greater than 2 mm, elevation or depression, discoloration, suture or staple marks, and overall poor appearance. A total cosmetic score was then calculated by adding the individual scores on each of the five categories ranging from 0 (worst) to 5 (best). Scars were also scored on a validated 100-mm visual analogue scale marked "worst scar" and "best scar" at the low and high ends, respectively. Pairwise interobserver agreement was calculated. RESULTS: Interobserver agreement for the total scores on the scar evaluation scale was 0.73, 0.75, and 0.85 (p < 0.001 for all). Interobserver correlations on the visual analogue scale were 0.83, 0.86, and 0.87 (p < 0.001 for all). Correlations between the total scar evaluation scale and visual analogue scale scores were 0.75, 0.86, and 0.92. Visual analogue scale scores were significantly higher as scar evaluation scale scores increased (analysis of variance, p < 0.001). CONCLUSION: The authors describe a new long-term scar evaluation scale that is highly reliable and correlated with the cosmetic visual analogue scale, suggesting construct validity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.prs.0000287275.15511.10

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Singer, A. J., Arora, B., Dagum, A., Valentine, S., & Hollander, J. E.
Venue
Plastic and Reconstructive Surgery
Published
2007-12
Volume
120
Issue
7
Pages
1892-1897
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2084113206
Cited by
238
References
10
FWCI
3.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.