The DOI matches its Crossref record.
Detection of Individual Microbubbles of Ultrasound Contrast Agents: Imaging of Free-Floating and Targeted Bubbles
Abstract
RATIONALE AND OBJECTIVES: During echo examinations with microbubble contrast, individual "dots" of ultrasound reflection can be visualized. To address the question whether these signals represent individual microbubbles, very dilute suspensions of ultrasound contrast agents or individual microbubbles attached to Petri dishes were prepared and studied by ultrasound imaging. METHODS: Microbubble suspensions were diluted in saline and evaluated by a clinical ultrasound imaging system. Microbubble concentration was verified by Coulter counter. Single microbubble preparation on a Petri dish was established by streptavidin-biotin interaction under microscopy control and subjected to ultrasound imaging. RESULTS: Ultrasound of dilute microbubble dispersions demonstrated distinct white foci; concentration of these sites was consistent with signals from individual microbubbles as determined by Coulter. Individual microbubbles immobilized on polystyrene were also visualized by ultrasound. CONCLUSION: Ultrasound medical systems can resolve backscatter signals from individual microbubbles of ultrasound contrast, both in solution and in the targeted immobilized state, implying picogram sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Molecular Imaging Primer: Modalities, Imaging Agents, and Applications
James, M. L., & Gambhir, S. S. (2012) · Physiological Reviews · doi:10.1152/physrev.00049.2010 · Cited by 1,140
Microbubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Self-citationUltrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Molecular imaging for cancer diagnosis and surgery
Hussain, T., & Nguyen, Q. T. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.09.007 · Cited by 337
Metadata
- Authors
- Klibanov, A. L., Rasche, P. T., Hughes, M. S., Wojdyla, J. K., Galen, K. P., Wible, J. H., & Brandenburger, G. H.
- Venue
- Investigative Radiology
- Published
- 2004-03
- Volume
- 39
- Issue
- 3
- Pages
- 187-195
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2071700707
- Cited by
- 199
- References
- 0
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Individual Microbubbles of Ultrasound Contrast Agents: Imaging of Free-Floating and Targeted Bubbles. https://app.cochat.ai/papers/10.1097/01.rli.0000115926.96796.75
- The paper
- Klibanov, A. L., Rasche, P. T., Hughes, M. S., Wojdyla, J. K., Galen, K. P., Wible, J. H., & Brandenburger, G. H. (2004). Detection of Individual Microbubbles of Ultrasound Contrast Agents: Imaging of Free-Floating and Targeted Bubbles. Investigative Radiology. https://doi.org/10.1097/01.rli.0000115926.96796.75
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.