The DOI matches its Crossref record.
Intraoperative Lymphography Using Indocyanine Green Dye for Near-Infrared Fluorescence Labeling in Lymphedema
Abstract
In Brief A new method for easy detection of functional lymphatic vessels in the superficial layer is reported. In a clinical trial, lymphography using indocyanine green dye for near-infrared fluorescence labeling in lymphaticovenular anastomoses was performed in 5 patients with lymphedema. The technique is simple and enables a minimally invasive operation to be performed. The results indicate that this technique is useful for acceptance as one of the examinations to evaluation of lymphedema. Intraoperative lymphography with indocyanine green dye for near-infrared fluorescence was performed on 5 patients. The study identified suitable locations for microvascular lymphaticovenular anastomoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chang, D. W., Suami, H., & Skoracki, R. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a4d626 · Cited by 525
Yamamoto, T., Narushima, M., Doi, K., Oshima, A., Ogata, F., Mihara, M., Koshima, I., & Mundinger, G. S. (2011) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e31820cf5df · Cited by 426
Self-citationNagaya, T., Nakamura, Y. A., Choyke, P. L., & Kobayashi, H. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00314 · Cited by 398
Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341
Mihara, M., Hara, H., Araki, J., Kikuchi, K., Narushima, M., Yamamoto, T., Iida, T., Yoshimatsu, H., Murai, N., Mitsui, K., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038182 · Cited by 290
Self-citation
Metadata
- Authors
- Ogata, F., Narushima, M., Mihara, M., Azuma, R., Morimoto, Y., & Koshima, I.
- Venue
- Annals of Plastic Surgery
- Published
- 2007-08
- Volume
- 59
- Issue
- 2
- Pages
- 180-184
- ISSN
- 0148-7043 (ISSN-L)
- OpenAlex
- W2062545425
- Cited by
- 205
- References
- 0
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative Lymphography Using Indocyanine Green Dye for Near-Infrared Fluorescence Labeling in Lymphedema. https://app.cochat.ai/papers/10.1097/01.sap.0000253341.70866.54
- The paper
- Ogata, F., Narushima, M., Mihara, M., Azuma, R., Morimoto, Y., & Koshima, I. (2007). Intraoperative Lymphography Using Indocyanine Green Dye for Near-Infrared Fluorescence Labeling in Lymphedema. Annals of Plastic Surgery. https://doi.org/10.1097/01.sap.0000253341.70866.54
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.