The DOI matches its Crossref record.
Evidence-Based Compression: Prevention of Stasis and Deep Vein Thrombosis
Open accessAbstract
In Brief Objective: To summarize the currently published scientific evidence for the venous flow effects of mechanical devices, particularly intermittent pneumatic compression, and the relation to prevention of deep vein thrombosis (DVT). Summary Background Data: While intermittent pneumatic compression is an established method of DVT prophylaxis, the variety of systems that are available can use very different compression techniques and sequences. In order for appropriate choices to be made to provide the optimum protection for patients, the general performance of systems, and physiological effects of particular properties, must be analyzed objectively. Methods: Medline was searched from 1970 to 2002, and all relevant papers were searched for further appropriate references. Papers were selected for inclusion when they addressed specifically the questions posed in this review. Results: All the major types of intermittent compression systems are successful in emptying deep veins of the lower limb and preventing stasis in a variety of subject groups. Compression stockings appear to function more by preventing distension of veins. Rapid inflation, high pressures, and graded sequential intermittent compression systems will have particular augmentation profiles, but there is no evidence that such features improve the prophylactic ability of the system. Conclusions: The most important factors in selecting a mechanical prophylactic system, particularly during and after surgery, are patient compliance and the appropriateness of the site of compression. There is no evidence that the peak venous velocity produced by a system is a valid measure of medical performance. Intermittent pneumatic systems for prevention of deep vein thrombosis will have different hemodynamic effects depending on their design. While all systems have been shown to be effective prophylaxis, there is no evidence that a particular compression sequence or construction is more effective than any other in preventing thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Pineo, G. F., Heit, J. A., Bergqvist, D., Lassen, M. R., Colwell, C. W., & Ray, J. G. (2004) · Chest · doi:10.1378/chest.126.3_suppl.338s · Cited by 5,895
Prevention of Venous Thromboembolism
Geerts, W. H., Bergqvist, D., Pineo, G. F., Heit, J. A., Samama, C. M., Lassen, M. R., & Colwell, C. W. (2008) · Chest · doi:10.1378/chest.08-0656 · Cited by 3,829
Knudson, M. M., Ikossi, D. G., Khaw, L., Morabito, D., & Speetzen, L. S. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000137138.40116.6c · Cited by 489
Reduced physical activity increases intermuscular adipose tissue in healthy young adults
Manini, T. M., Clark, B. C., Nalls, M. A., Goodpaster, B. H., Ploutz-Snyder, L. L., & Harris, T. B. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.2.377 · Cited by 332
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Metadata
- Authors
- Morris, R. J., & Woodcock, J. P.
- Venue
- Annals of Surgery
- Published
- 2004-02
- Volume
- 239
- Issue
- 2
- Pages
- 162-171
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2158607342
- Cited by
- 221
- References
- 0
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence-Based Compression: Prevention of Stasis and Deep Vein Thrombosis. https://app.cochat.ai/papers/10.1097/01.sla.0000109149.77194.6c
- The paper
- Morris, R. J., & Woodcock, J. P. (2004). Evidence-Based Compression: Prevention of Stasis and Deep Vein Thrombosis. Annals of Surgery. https://doi.org/10.1097/01.sla.0000109149.77194.6c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.