How Should Transection of the Liver Be Performed?: A Prospective Randomized Study in 100 Consecutive Patients: Comparing Four Different Transection Strategies
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
In Brief Objective: To identify the most efficient parenchyma transection technique for liver resection using a prospective randomized protocol. Summary Background Data: Liver resection can be performed by different transection devices with or without inflow occlusion (Pringle maneuver). Only limited data are currently available on the best transection technique. Methods: A randomized controlled trial was performed in noncirrhotic and noncholestatic patients undergoing liver resection comparing the clamp crushing technique with Pringle maneuver versus CUSA versus Hydrojet versus dissecting sealer without Pringle maneuver (25 patients each group). Primary endpoints were intraoperative blood loss, resection time, and postoperative liver injury. Secondary end points included the use of inflow occlusion, postoperative complications, and costs. Results: The clamp crushing technique had the highest transection velocity (3.9 ± 0.3 cm2/min) and lowest blood loss (1.5 ± 0.3 mL/cm2) compared with CUSA (2.3 ± 0.2 cm2/min and 4 ± 0.7 mL/cm2), Hydrojet (2.4 ± 0.3 cm2/min and 3.5 ± 0.5 mL/cm2), and dissecting sealer (2.5 ± 0.3 cm2/min and 3.4 ± 0.4 mL/cm2) (velocity: P = 0.001; blood loss: P = 0.003). Clamp crushing technique was associated with the lowest need for postoperative blood transfusions. The degree of postoperative reperfusion injury and complications were not significantly different among the groups. The clamp crushing technique proved to be most cost-efficient device and had a cost-saving potential of 600 € to 2400 € per case. Conclusions: The clamp crushing technique was the most efficient device in terms of resection time, blood loss, and blood transfusion frequency compared with CUSA, Hydrojet, and dissecting sealer, and proved to be also the most cost-efficient device. Clamp crushing technique for liver transection was associated with a shorter resection time, less blood loss, and a lower blood transfusion frequency compared to CUSA, Hydrojet, and dissecting sealer in noncirrhotic and noncholestatic patients. Furthermore, the clamp crushing technique proved to be the most cost-efficient device of all 4 tested transection devices regardless of the case load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dindo, D., Demartines, N., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000133083.54934.ae · Cited by 31,378
Self-citation(2011) · Hepatogastroenterology · doi:10.5754/hge11589 · Cited by 1,756
Jarnagin, W. R., Gönen, M., Fong, Y., DeMatteo, R. P., Ben‐Porat, L., Little, S., Corvera, C. U., Weber, S., & Blumgart, L. H. (2002) · PubMed · doi:10.1097/01.sla.0000029003.66466.b3 · Cited by 1,474
NOTES ON THE ARREST OF HEPATIC HEMORRHAGE DUE TO TRAUMA
PRINGLE, J. H. (1908) · Annals of Surgery · doi:10.1097/00000658-190810000-00005 · Cited by 1,267
Belghiti, J., Hiramatsu, K., Benoist, S., Massault, P. P., Sauvanet, A., & Farges, O. (2000) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(00)00261-1 · Cited by 1,051
Poon, R. T., Fan, S. T., Lo, C. M., Liu, C. L., Lam, C. M., Yuen, W. K., Yeung, C., & Wong, J. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000141195.66155.0c · Cited by 677
Melendez, J. A., Arslan, V., Fischer, M. E., Wuest, D., Jarnagin, W. R., Fong, Y., & Blumgart, L. H. (1998) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(98)00240-3 · Cited by 576
Kooby, D. A., Stockman, J., Ben-Porat, L., Gonen, M., Jarnagin, W. R., Dematteo, R. P., Tuorto, S., Wuest, D., Blumgart, L. H., & Fong, Y. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000072371.95588.da · Cited by 571
Clavien, P.-A., Selzner, M., Rüdiger, H. A., Graf, R., Kadry, Z., Rousson, V., & Jochum, W. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000098620.27623.7d · Cited by 492
Self-citationClavien, P.-A., Yadav, S., Sindram, D., & Bentley, R. C. (2000) · Annals of Surgery · doi:10.1097/00000658-200008000-00001 · Cited by 472
Self-citationPerioperative blood transfusion promotes recurrence of hepatocellular carcinoma after hepatectomy.
Yamamoto, J., Kosuge, T., Takayama, T., et al. (1994) · PubMed · Cited by 302
One Hundred Consecutive Hepatic Resections: Blood Loss, Transfusion, and Operative Technique
Cunningham, J. D. (1994) · Archives of Surgery · doi:10.1001/archsurg.1994.01420340064011 · Cited by 262
A Simplified Technique for Hepatic Resection
Lin, T.-Y. (1974) · Annals of Surgery · doi:10.1097/00000658-197409000-00005 · Cited by 126
Cited by
The Clavien-Dindo Classification of Surgical Complications: Five-Year Experience
Clavien, P. A., Barkun, J., de Oliveira, M. L., Vauthey, J. N., Dindo, D., Schulick, R. D., de Santibañes, E., Pekolj, J., Slankamenac, K., Bassi, C., et al. (2009) · Annals of Surgery · doi:10.1097/sla.0b013e3181b13ca2 · Cited by 11,482
Self-citationMcCormack, L., Petrowsky, H., Jochum, W., Furrer, K., & Clavien, P.-A. (2007) · Annals of Surgery · doi:10.1097/01.sla.0000251747.80025.b7 · Cited by 309
Self-citationBeck-Schimmer, B., Breitenstein, S., Urech, S., De Conno, E., Wittlinger, M., Puhan, M., Jochum, W., Spahn, D. R., Graf, R., & Clavien, P.-A. (2008) · Annals of Surgery · doi:10.1097/sla.0b013e31818f3dda · Cited by 251
“Liver transsection was performed by parenchyma crushing using a small Kelly clamp (3-mm diameter tip).(6) Small vessels ( 2 mm) were coagulated with the irrigated bipolar forceps set at 120 W, whereas all other structures including major intrahepatic bile ducts were ligated or clipped.”
MethodSelf-citationCurrent treatment for colorectal liver metastases
Misiakos, E. P. (2011) · World Journal of Gastroenterology · doi:10.3748/wjg.v17.i36.4067 · Cited by 170
Schwarz, C., Klaus, D. A., Tudor, B., Fleischmann, E., Wekerle, T., Roth, G., Bodingbauer, M., & Kaczirek, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140314 · Cited by 19
“2 cm(2)/min for CUSA resection) in transection speed observed in a prospective study evaluating different techniques including clamp-crush resection with vascular occlusion (comparable to speed of stapler hepatectomy) and CUSA resection [21] to achieve an alpha of 0.”
Background
Metadata
- Authors
- Lesurtel, M., Selzner, M., Petrowsky, H., McCormack, L., & Clavien, P.-A.
- Venue
- Annals of Surgery
- Published
- 2005-12
- Volume
- 242
- Issue
- 6
- Pages
- 814-823
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2041956518
- Cited by
- 297
- References
- 13
- FWCI
- 12.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.