The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Prospective Validation of Computed Tomographic Screening of the Thoracolumbar Spine in Trauma
Abstract
OBJECTIVE: Concern for thoracolumbar spine (TLS) injuries after major trauma mandates immobilization pending radiographic evaluation. Current protocols use standard posteroanterior and lateral radiographs of the thoracolumbar spine (XR/TLS), but many patients also undergo abdominal or thoracic computed tomographic (CT) scanning. We sought to evaluate whether helical truncal CT scanning performed to evaluate visceral trauma images the spine as well as dedicated XR/TLS. METHODS: We prospectively studied 222 consecutive patients sustaining high-risk trauma requiring TLS screening because of clinical findings or altered mentation. The chest, abdomen, and pelvis were imaged with one intravenous contrast infusion. All patients had CT scan of the chest, abdomen, and pelvis (CT/CAP) and XR/TLS. Initial radiologic diagnoses were compared with the discharge diagnosis of acute fractures confirmed by thin-cut CT scan and/or clinical examination of the patient when alert. RESULTS: Of 222 patients studied, 215 were fully evaluated. Thirty-six (17%) had acute TLS fractures. The accuracy of CT/CAP for TLS fractures was 99% (95% confidence interval [CI], 96-100%). The accuracy of XR/TLS was 87% (95% CI, 82-92%). Sensitivity, specificity, and positive and negative predictive values were better for CT/CAP than for XR/TLS. CT/CAP found acute fractures XR/TLS missed, and correctly classified old fractures XR/TLS read as "possibly" acute. The total XR/TLS misclassification rate was 12.6% (95% CI, 8.4-19%); for CT/CAP it was 1.4% (95% CI, 0.3-3.3%). No fractures were missed by CT/CAP. No unstable fracture was missed by either technique. CONCLUSION: CT/CAP diagnoses TLS fractures more accurately than XR/TLS. Neither misses unstable fractures, but CT scanning finds small fractures that benefit by treatment and identifies chronic disease better. CT screening is far faster and shortens time to removal of spine precautions. CT scan-based diagnosis does not result in greater radiation exposure and improves resource use. Screening the TLS on truncal helical CT scanning performed for the evaluation of visceral injuries is more accurate than TLS imaging by standard radiography. CT/CAP should replace plain radiographs in high-risk trauma patients who require screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Cited by
Management of thoracolumbar spine fractures
Wood, K. B., Li, W., Lebl, D. S., & Ploumis, A. (2014) · The Spine Journal · doi:10.1016/j.spinee.2012.10.041 · Cited by 504
Metadata
- Authors
- Hauser, C. J., Visvikis, G., Hinrichs, C., Eber, C. D., Cho, K., Lavery, R. F., & Livingston, D. H.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 2003-08
- Volume
- 55
- Issue
- 2
- Pages
- 228-235
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W1967846001
- Cited by
- 200
- References
- 1
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective Validation of Computed Tomographic Screening of the Thoracolumbar Spine in Trauma. https://app.cochat.ai/papers/10.1097/01.ta.0000076622.19246.cf
- The paper
- Hauser, C. J., Visvikis, G., Hinrichs, C., Eber, C. D., Cho, K., Lavery, R. F., & Livingston, D. H. (2003). Prospective Validation of Computed Tomographic Screening of the Thoracolumbar Spine in Trauma. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/01.ta.0000076622.19246.cf
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.