The DOI matches its Crossref record.
Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients?
Abstract
BACKGROUND: Our recent experimental study showed that peripheral muscle tissue oxygen saturation (StO2), determined noninvasively by near-infrared spectroscopy (NIRS), was more reliable than systemic hemodynamics or invasive oxygenation variables as an index of traumatic shock. The purpose of this study was to establish the normal range of thenar muscle StO2 in humans and the relationship between shock state and StO2 in trauma patients. METHODS: This was a prospective, nonrandomized, observational, descriptive study in normal human volunteers (n = 707) and patients admitted to the resuscitation area of our Level I trauma center (n = 150). To establish a normal StO2 range, an NIRS probe was applied to the thenar eminence of volunteers (normals). Subsequently, in a group of trauma patients, an NIRS probe was applied to the thenar eminence and data were collected and stored for offline analysis. StO2 monitoring was performed continuously and noninvasively, and values were recorded at 2-minute intervals. Five moribund trauma patients were excluded. Members of our trauma faculty, blinded to StO2 values, classified each patient into one of four groups (no shock, mild shock, moderate shock, and severe shock) using conventional physiologic parameters. RESULTS: Mean +/- SD thenar StO2 values for each group were as follows: normals, 87 +/- 6% (n = 707); no shock, 83 +/- 10% (n = 85); mild shock, 83 +/- 10% (n = 19); moderate shock, 80 +/- 12% (n = 14); and severe shock, 45 +/- 26% (n = 14). The thenar StO2 values clearly discriminated the normals or no shock patients and the patients with severe shock (p < 0.05). CONCLUSION: Decreased thenar muscle tissue oxygen saturation reflects the presence of severe hypoperfusion and near-infrared spectroscopy may be a novel method for rapidly and noninvasively assessing changes in tissue dysoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Cohn, S. M., Nathens, A. B., Moore, F. A., Rhee, P., Puyana, J. C., Moore, E. E., & Beilman, G. J. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802eb817 · Cited by 294
Self-citationGómez, H., Mesquida, J., Simon, P., Kim, H. K., Puyana, J. C., Ince, C., & Pinsky, M. R. (2009) · Critical Care · doi:10.1186/cc8001 · Cited by 94
Metadata
- Authors
- Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., Soffer, D., Habib, F., Schulman, C. I., Duncan, R., & Proctor, K. G.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 2005-04
- Volume
- 58
- Issue
- 4
- Pages
- 806-816
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2002010869
- Cited by
- 211
- References
- 0
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients? https://app.cochat.ai/papers/10.1097/01.ta.0000158269.68409.1c
- The paper
- Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., Soffer, D., Habib, F., Schulman, C. I., Duncan, R., & Proctor, K. G. (2005). Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients? The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/01.ta.0000158269.68409.1c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.