CoChat

Insights from ambulatory blood pressure monitoring: diagnosis of hypertension and diurnal blood pressure in renal transplant recipients

Haydar, Ali A., Covic, Adrian, Jayawardene, Satish, Agharazii, Mohsen, Smith, Eilish, Gordon, Isabel, O’Sullivan, Helen, Goldsmith, David J. A. · 2004 · Transplantation
Cited by 55

The DOI matches its Crossref record.

Abstract

BACKGROUND: Accurate diagnosis of hypertension is essential in chronic kidney disease patients, as it is linked to increased left ventricular mass, stroke, cardiovascular mortality and morbidity, and progression to end-stage renal disease. Elevated blood pressure (BP) detected by ambulatory BP monitoring (ABPM) has been shown to be predictive of worse outcome in chronic kidney disease patients. Another predictor of worse outcome is diurnal BP variation, measured also by ABPM. In this study, the authors examined the relationship (concordance or discordance) between blood pressure measured by ABPM compared with daytime office BP, and also explored the predictors of diurnal variation in renal transplant recipients. METHODS: All the patients who underwent renal transplantation and follow-up at the authors' institution from January 1998 to January 2003 were involved in this study (n=177) in addition to another randomly selected 64 patients that underwent transplantation before 1998. All patients had their ABPM performed according to previously described protocols at least 2 weeks after discharge from the hospital, dialysis-independent and with a functioning renal allograft. RESULTS: The authors found a positive correlation between systolic BP (SBP) diurnal variation and age (r =0.263, P <0.0001), glomerular filtration rate (GFR) (r =-0.229, P <0.0001), cyclosporine trough (r =0.171, P =0.047), and ABPM-to-transplant interval (r =-0.133, P =0.039). After fitting a regression model, the authors found that only GFR (P <0.0001) and age (P =0.001) were independent predictors of SBP diurnal variation (r =0.357). Concordance rate between casual BP and ABPM was 80%, and by using casual BP, only 15% of hypertensive renal transplant patients would be erroneously diagnosed as normotensive. CONCLUSIONS: The authors found that SBP diurnal variation is predicted independently by age and GFR, although it does correlate with cyclosporine trough and ABPM-to-transplant interval. In addition, the authors showed that ABPM is a more sensitive method for diagnosing hypertension than is sole reliance on office BP in renal transplant recipients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.tp.0000115345.16853.51

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 55

Metadata

Authors
Haydar, A. A., Covic, A., Jayawardene, S., Agharazii, M., Smith, E., Gordon, I., O’Sullivan, H., & Goldsmith, D. J. A.
Venue
Transplantation
Published
2004-03-27
Volume
77
Issue
6
Pages
849-853
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2086170934
Cited by
55
References
0
FWCI
1.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Insights from ambulatory blood pressure monitoring: diagnosis of hypertension and diurnal blood pressure in renal transplant recipients. https://app.cochat.ai/papers/10.1097/01.tp.0000115345.16853.51
The paper
Haydar, A. A., Covic, A., Jayawardene, S., Agharazii, M., Smith, E., Gordon, I., O’Sullivan, H., & Goldsmith, D. J. A. (2004). Insights from ambulatory blood pressure monitoring: diagnosis of hypertension and diurnal blood pressure in renal transplant recipients. Transplantation. https://doi.org/10.1097/01.tp.0000115345.16853.51

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.