Amiodarone and Optic Neuropathy: The Heart of the Matter
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Amiodarone is one of the most effective antiarrhythmic drugs currently available. Although a subject of intense controversy, a causal link between amiodarone and optic neuropathy has never been firmly established. Indications for treatment with amiodarone are outlined, and features of the optic neuropathy in patients on amiodarone are compared with those of nonarteritic anterior ischemic optic neuropathy. An approach to patients treated with amiodarone who present with optic neuropathy is outlined, and suggestions for a registry and prospective study of such patients are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489 · cited 1×
“Implantable cardioverter defibrillators (ICD) are the first-line therapy for both primary and secondary prevention (7,8).”
BackgroundFeatures of amiodarone-induced optic neuropathy
Macaluso, D. C., Shults, W. T., & Fraunfelder, F. T. (1999) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00016-1 · Cited by 98
Cited by
Hayreh, S. S. (2009) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.11.002 · Cited by 656
“Moreover, there are reports of patients with asymptomatic ODE progressing to visual loss after amiodarone had been discontinued (Murphy and Murphy, 2005).”
BackgroundBiousse, V., & Newman, N. J. (2015) · New England Journal of Medicine · doi:10.1056/nejmra1413352 · Cited by 341
Miller, N. R., & Arnold, A. C. (2015) · Eye · doi:10.1038/eye.2014.144 · Cited by 245
Rucker, J. C., Biousse, V., & Newman, N. J. (2004) · Current Opinion in Neurology · doi:10.1097/00019052-200402000-00006 · Cited by 206
Treatment of Nonarteritic Anterior Ischemic Optic Neuropathy
Atkins, E. J., Bruce, B. B., Newman, N. J., & Biousse, V. (2010) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.06.008 · Cited by 181
Metadata
- Authors
- Murphy, M. A., & Murphy, J. F.
- Venue
- Journal of Neuro-Ophthalmology
- Published
- 2005-09
- Volume
- 25
- Issue
- 3
- Pages
- 232-236
- ISSN
- 1070-8022 (ISSN-L)
- OpenAlex
- W2003353170
- Cited by
- 67
- References
- 3
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.