New Chronic EEG Electrode for Critical/Intensive Care Unit Monitoring
The DOI matches its Crossref record.
Abstract
The main limiting factor of EEG monitoring in the critical/intensive care environments is, and always has been, the recording electrode. The electrode and its application to the scalp has changed very little since EEG was first discovered and developed as a clinical tool. However, the evolution of amplifiers and data acquisition systems have made tremendous strides. Modern-day EEG recording systems now have the capability to record for days and weeks with little intervention, whereas the EEG electrode requires constant attention and skilled adjustment every 10 to 24 hours. If one surveys the vast array of electrodes used now and in the past, the only electrode that, once placed, never needed any further adjustment for days and weeks on end, was the chronic silver-silver/chloride (Ag-Ag/Cl) sphenoidal (Sp) electrode. This Sp electrode has now been modified to permit it to be placed subdermally, similar to that of a subdermal needle electrode, but now the needle is removed to leave in place a fine, flexible, durable, chronic Ag-Ag/Cl electrode. Once placed, this subdermal wire electrode (SWE, patent pending) starts to record immediately with a low impedance of 3 to 4 Komega. This electrode can record any biopotential, in humans and in animals, and in most recording environments; it never needs adjustment, and records high-quality biopotential signals for as long as it is left in place. The SWE is also MRI and computed-tomography compatible. It takes less than half the time to place the SWE, and placement can now be performed by any medically trained personnel to obtain a low-maintenance, high-quality EEG recording.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Evaluation and Management of Status Epilepticus
Neurocritical Care Society Status Epilepticus Guideline Writing Committee, Brophy, G. M., Bell, R., Claassen, J., Alldredge, B., Bleck, T. P., Glauser, T., LaRoche, S. M., Riviello, J. J., Shutter, L., et al. (2012) · Neurocritical Care · doi:10.1007/s12028-012-9695-z · Cited by 1,623
Meikle, L., Talos, D. M., Onda, H., Pollizzi, K., Rotenberg, A., Sahin, M., Jensen, F. E., & Kwiatkowski, D. J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5540-06.2007 · Cited by 462
Wearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404
Continuous Electroencephalogram Monitoring in the Intensive Care Unit
Friedman, D., Claassen, J., & Hirsch, L. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a9d8b5 · Cited by 309
Huggins, J. E., Wren, P. A., & Gruis, K. L. (2011) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482968.2011.572978 · Cited by 215
Metadata
- Authors
- Ives, J. R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2005-04
- Volume
- 22
- Issue
- 2
- Pages
- 119-123
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2048040179
- Cited by
- 69
- References
- 0
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Chronic EEG Electrode for Critical/Intensive Care Unit Monitoring. https://app.cochat.ai/papers/10.1097/01.wnp.0000152659.30753.47
- The paper
- Ives, J. R. (2005). New Chronic EEG Electrode for Critical/Intensive Care Unit Monitoring. Journal of Clinical Neurophysiology. https://doi.org/10.1097/01.wnp.0000152659.30753.47
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.