Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Management of One-lung Ventilation: Impact of Tidal Volume on Complications after Thoracic Surgery

Blank, Randal S., Colquhoun, Douglas A., Durieux, Marcel E., Kozower, Benjamin D., McMurry, Timothy L., Bender, S. Patrick, Naik, Bhiken I. · 2016 · Anesthesiology

Abstract

AbstractAbstract: Analysis from 1,019 patients undergoing one-lung ventilation indicated that low tidal volume in the presence of low positive end-expiratory pressure is associated with increased pulmonary complications. This suggests that low tidal volume during one-lung ventilation is protective only when accompanied by adequate positive end-expiratory pressure. Background: The use of lung-protective ventilation (LPV) strategies may minimize iatrogenic lung injury in surgical patients. However, the identification of an ideal LPV strategy, particularly during one-lung ventilation (OLV), remains elusive. This study examines the role of ventilator management during OLV and its impact on clinical outcomes. Methods: Data were retrospectively collected from the hospital electronic medical record and the Society of Thoracic Surgery database for subjects undergoing thoracic surgery with OLV between 2012 and 2014. Mean tidal volume (V T) during two-lung ventilation and OLV and ventilator driving pressure (ΔP) (plateau pressure − positive end-expiratory pressure [PEEP]) were analyzed for the 1,019 cases that met the inclusion criteria. Associations between ventilator parameters and clinical outcomes were examined by multivariate linear regression. Results: After the initiation of OLV, 73.3, 43.3, 18.8, and 7.2% of patients received V T greater than 5, 6, 7, and 8 ml/kg predicted body weight, respectively. One hundred and eighty-four primary and 288 secondary outcome events were recorded. In multivariate logistic regression modeling, V T was inversely related to the incidence of respiratory complications (odds ratio, 0.837; 95% CI, 0.729 to 0.958), while ΔP predicted the development of major morbidity when modeled with V T (odds ratio, 1.034; 95% CI, 1.001 to 1.068). Conclusions: Low V T per se (i.e., in the absence of sufficient PEEP) has not been unambiguously demonstrated to be beneficial. The authors found that a large proportion of patients continue to receive high V T during OLV and that V T was inversely related to the incidence of respiratory complications and major postoperative morbidity. While low (physiologically appropriate) V T is an important component of an LPV strategy for surgical patients during OLV, current evidence suggests that, without adequate PEEP, low V T does not prevent postoperative respiratory complications. Thus, use of physiologic V T may represent a necessary, but not independently sufficient, component of LPV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000001100

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 177

Metadata

Authors
Blank, R. S., Colquhoun, D. A., Durieux, M. E., Kozower, B. D., McMurry, T. L., Bender, S. P., & Naik, B. I.
Venue
Anesthesiology
Published
2016-06
Volume
124
Issue
6
Pages
1286-1295
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2304440479
Cited by
177
References
3
FWCI
15.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Management of One-lung Ventilation: Impact of Tidal Volume on Complications after Thoracic Surgery. https://app.cochat.ai/papers/10.1097/aln.0000000000001100
The paper
Blank, R. S., Colquhoun, D. A., Durieux, M. E., Kozower, B. D., McMurry, T. L., Bender, S. P., & Naik, B. I. (2016). Management of One-lung Ventilation: Impact of Tidal Volume on Complications after Thoracic Surgery. Anesthesiology. https://doi.org/10.1097/aln.0000000000001100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.