CoChat

Associations of Intraoperative Radial Arterial Systolic, Diastolic, Mean, and Pulse Pressures with Myocardial and Acute Kidney Injury after Noncardiac Surgery: A Retrospective Cohort Analysis

Open access
Ahuja, Sanchit, Mascha, Edward J., Yang, Dongsheng, Maheshwari, Kamal, Cohen, Barak, Khanna, Ashish K., Ruetzler, Kurt, Turan, Alparslan, Sessler, Daniel I. · 2020 · Anesthesiology
Cited by 186

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: Background: Arterial pressure is a complex signal that can be characterized by systolic, mean, and diastolic components, along with pulse pressure (difference between systolic and diastolic pressures). The authors separately evaluated the strength of associations among intraoperative pressure components with myocardial and kidney injury after noncardiac surgery. Methods: The authors included 23,140 noncardiac surgery patients at Cleveland Clinic who had blood pressure recorded at 1-min intervals from radial arterial catheters. The authors used univariable smoothing and multivariable logistic regression to estimate probabilities of each outcome as function of patients’ lowest pressure for a cumulative 5 min for each component, comparing discriminative ability using C-statistics. The authors further assessed the association between outcomes and both area and minutes under derived thresholds corresponding to the beginning of increased risk for the average patient. Results: Out of 23,140 patients analyzed, myocardial injury occurred in 6.1% and acute kidney injury in 8.2%. Based on the lowest patient blood pressure experienced for greater than or equal to 5 min, estimated thresholds below which the odds of myocardial or kidney injury progressively increased (slope P < 0.001) were 90 mmHg for systolic, 65 mmHg for mean, 50 mmHg for diastolic, and 35 mmHg for pulse pressure. Weak discriminative ability was noted between the pressure components, with univariable C-statistics ranging from 0.55 to 0.59. Area under the curve in the highest (deepest) quartile of exposure below the respective thresholds had significantly higher odds of myocardial injury after noncardiac surgery and acute kidney injury compared to no exposure for systolic, mean, and pulse pressure (all P < 0.001), but not diastolic, after adjusting for confounding. Conclusions: Systolic, mean, and pulse pressure hypotension were comparable in their strength of association with myocardial and renal injury. In contrast, the relationship with diastolic pressure was poor. Baseline factors were much more strongly associated with myocardial and renal injury than intraoperative blood pressure, but pressure differs in being modifiable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000003048

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 186

Metadata

Authors
Ahuja, S., Mascha, E. J., Yang, D., Maheshwari, K., Cohen, B., Khanna, A. K., Ruetzler, K., Turan, A., & Sessler, D. I.
Venue
Anesthesiology
Published
2020-02
Volume
132
Issue
2
Pages
291-306
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2990264484
Cited by
186
References
1
FWCI
11.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Associations of Intraoperative Radial Arterial Systolic, Diastolic, Mean, and Pulse Pressures with Myocardial and Acute Kidney Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. https://app.cochat.ai/papers/10.1097/aln.0000000000003048
The paper
Ahuja, S., Mascha, E. J., Yang, D., Maheshwari, K., Cohen, B., Khanna, A. K., Ruetzler, K., Turan, A., & Sessler, D. I. (2020). Associations of Intraoperative Radial Arterial Systolic, Diastolic, Mean, and Pulse Pressures with Myocardial and Acute Kidney Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. Anesthesiology. https://doi.org/10.1097/aln.0000000000003048

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.