STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Background: Obstructive sleep apnea (OSA) is a major risk factor for perioperative adverse events. However, no screening tool for OSA has been validated in surgical patients. This study was conducted to develop and validate a concise and easy-to-use questionnaire for OSA screening in surgical patients. Methods: After hospital ethics approval, preoperative patients aged 18 yr or older and without previously diagnosed OSA were recruited. After a factor analysis, reliability check, and pilot study; four yes/no questions were used to develop this screening tool. The four questions were respectively related to snoring, tiredness during daytime, observed apnea, and high blood pressure (STOP). For validation, the score from the STOP questionnaire was evaluated versus the apnea-hypopnea index from monitored polysomnography. Results: The STOP questionnaire was given to 2,467 patients, 27.5% classified as being at high risk of OSA. Two hundred eleven patients underwent polysomnography, 34 for the pilot test and 177 for validation. In the validation group, the apnea-hypopnea index was 20 +/- 6. The sensitivities of the STOP questionnaire with apnea-hypopnea index greater than 5, greater than 15, and greater than 30 as cutoffs were 65.6, 74.3, and 79.5%, respectively. When incorporating body mass index, age, neck circumference, and gender into the STOP questionnaire, sensitivities were increased to 83.6, 92.9, and 100% with the same apnea-hypopnea index cutoffs. Conclusions: The STOP questionnaire is a concise and easy-to-use screening tool for OSA. It has been developed and validated in surgical patients at preoperative clinics. Combined with body mass index, age, neck size, and gender, it had a high sensitivity, especially for patients with moderate to severe OSA.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The STOP questionnaire is constructed in an even simpler format, with four yes or no questions corresponding to snoring, tiredness, observation (of apneas), and BP.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [446]
In the citing paper
“reports of other screening instruments have suggested minimal burden and disruption of the clinical workflow.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [446]
In the citing paper
“On the other hand, the specificity ranges from 30% to 43%, which may yield high false positive rates and may increase unnecessary testing.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [446]
In the citing paper
“However, they should not be used as a diagnostic tool without confirmatory sleep study testing given the low to moderate specificity and the potential for misdiagnosis.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [446]
In the citing paper
“One screening tool that incorporates NC is the STOP-BANG which is used to identify patients at high risk for OSA446 and uses NC or shirt collar size estimates with thresholds of 43 cm (17 inch) for males and 41 cm (16 inch) for females.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [446]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
McNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973 · cited 1×
“The Berlin questionnaire is one of the few questionnaires that have been validated in primary care patients.(30) However, instead of monitored polysomnography in a sleep laboratory, home portable sleep monitoring was used for the validation of the Berlin questionnaire.”
MethodSleep-disordered Breathing and Cardiovascular Disease
SHAHAR, E., WHITNEY, C. W., REDLINE, S., LEE, E. T., NEWMAN, A. B., JAVIER NIETO, F., O'CONNOR, G. T., BOLAND, L. L., SCHWARTZ, J. E., & SAMET, J. M. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.2001008 · Cited by 2,901 · cited 1×
“Studies have also shown that OSA is associated with a high risk for traffic accidents and cardiovascular disease.(3,4)”
BackgroundYoung, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
(2006) · Anesthesiology · doi:10.1097/00000542-200605000-00026 · Cited by 1,188 · cited 2×
“For example, there are 11 multiple-choice questions organized into three categories on the Berlin questionnaire,30 and 14 items under three categories on the OSA checklist, which is recommended by the ASA.43 Study has shown that the response rate among patients decreases with increasing length of the questionnaire.44…”
Association of Atrial Fibrillation and Obstructive Sleep Apnea
Gami, A. S., Pressman, G., Caples, S. M., Kanagala, R., Gard, J. J., Davison, D. E., Malouf, J. F., Ammash, N. M., Friedman, P. A., & Somers, V. K. (2004) · Circulation · doi:10.1161/01.cir.0000136587.68725.8e · Cited by 1,148
Access to Diagnosis and Treatment of Patients with Suspected Sleep Apnea
Flemons, W. W., Douglas, N. J., Kuna, S. T., Rodenstein, D. O., & Wheatley, J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1124pp · Cited by 670 · cited 1×
“growing awareness of sleep apnea has exacerbated the long waiting list in many sleep laboratories.(15) To deal with this issue, a number of screening questionnaires”
GUPTA, R. M., PARVIZI, J., HANSSEN, A. D., & GAY, P. C. (2001) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)62108-3 · Cited by 623
The Sleep Disorders Questionnaire I: Creation and Multivariate Structure of SDQ
Douglass, A. B., Bomstein, R., Nino-Murcia, G., Keenan, S., Miles, L., Zarcone, V. P., Guilleminault, C., & Dement, W. C. (1994) · Sleep · doi:10.1093/sleep/17.2.160 · Cited by 559 · cited 1×
“For the questionnaire tested in sleep center patients, the sensitivity varied from 70% to 93%.(25,41,42) The Berlin questionnaire is the most widely tested screening tool for OSA.”
Cited by
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
Breast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Diagnosis and Management of Obstructive Sleep Apnea: A Review
Gottlieb, D. J., & Punjabi, N. M. (2020) · JAMA · doi:10.1001/jama.2020.3514 · Cited by 1,482
Chung, F., Abdullah, H. R., & Liao, P. (2016) · Chest · doi:10.1378/chest.15-0903 · Cited by 1,362
“The STOP and STOP-Bang Questionnaire The snoring, tiredness, observed apnea, high BP (STOP) and snoring, tiredness, observed apnea, high BP-BMI, age, neck circumference and gender (STOPBang) questionnaires (e-Appendix 1) were developed in response to the need for a concise, user-friendly OSA screening tool in preopera…”
BackgroundMethodInfluentialSelf-citationYoung, T. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.8.893 · Cited by 1,304
Metadata
- Authors
- Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M.
- Affiliations
- University Health Network (CA)
- Research Fellow.
- Research Data Analyst.
- Research Coordinator, Department of Anesthesia.
- Venue
- Anesthesiology
- Published
- 2008-05-01
- Volume
- 108
- Issue
- 5
- Pages
- 812-821
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2125397756
- Semantic Scholar
- 188cd48b2ab7ae78297a051c8a334df6b38a58a1
- Cited by
- 2,355
- References
- 43
- Citations by year
- 2026: 162 · 2025: 166 · 2024: 151 · 2023: 170 · 2022: 173 · 2021: 191 · 2020: 153 · 2019: 144 · 2018: 152 · 2017: 138 · 2016: 149 · 2015: 135 · 2014: 125 · 2013: 105 · 2012: 94
- FWCI
- 32.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Keywords
- obstructive sleep apnea, STOP questionnaire, OSA screening, surgical patients, preoperative screening, apnea-hypopnea index, polysomnography, snoring, daytime fatigue, hypertension, body mass index, neck circumference, screening tool validation
- MeSH terms
- Female, Humans, Male, Mass Screening, Surveys and Questionnaires, Body Mass Index, Polysomnography, Sleep Apnea, Obstructive, Body Size
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.