Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 296

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery

Dyer, Robert A., Reed, Anthony R., van Dyk, Dominique, Arcache, Michelle J., Hodges, Owen, Lombard, Carl J., Greenwood, Jaime, James, Michael F.·2009·Anesthesiology

Abstract

Background: Hemodynamic responses to vasopressors used during spinal anesthesia for elective Cesarean delivery, have not been well described. This study compared the effects of bolus phenylephrine and ephedrine on maternal cardiac output (CO). The hypothesis was that phenylephrine, but not ephedrine, decreases CO when administered in response to hypotension during spinal anesthesia. Methods: Forty-three patients were randomized to receive 80 microg of phenylephrine or 10 mg of ephedrine. Both pulse wave form analysis and transthoracic bioimpedance changes were used to estimate stroke volume in each patient. Hemodynamic responses to spinal anesthesia and oxytocin were also recorded. A subgroup of 20 patients was randomized to receive oxytocin compared with oxytocin plus 80 microg of phenylephrine after delivery. Results: Mean CO and maximum absolute response in CO were significantly lower during the 150 s after phenylephrine administration than after ephedrine (6.2 vs. 8.1 l/min, P = 0.001, and 5.2 vs. 9.0 l/min, P < 0.0001, respectively for pulse wave form analysis, and 5.2 vs. 6.3 l/min, P = 0.01 and 4.5 vs. 6.7 l/min, P = 0.0001, respectively for bioimpedance changes). CO changes correlated with heart rate changes. Coadministration of phenylephrine obtunded oxytocin-induced decreases in systemic vascular resistance and increases in heart rate and CO. Trends in CO change were similar using either monitor. Conclusions: Bolus phenylephrine reduced maternal CO, and decreased CO when compared with ephedrine during elective spinal anesthesia for Cesarean delivery. CO changes correlated with heart rate changes after vasopressor administration, emphasizing the importance of heart rate as a surrogate indicator of CO. Coadministered phenylephrine obtunded hemodynamic responses to oxytocin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3181b437e0

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 296

Metadata

Authors
Dyer, R. A., Reed, A. R., van Dyk, D., Arcache, M. J., Hodges, O., Lombard, C. J., Greenwood, J., & James, M. F.
Venue
Anesthesiology
Published
2009-10-01
Volume
111
Issue
4
Pages
753-765
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2120330172
Cited by
296
References
1
FWCI
19.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery. https://app.cochat.ai/papers/10.1097/aln.0b013e3181b437e0
The paper
Dyer, R. A., Reed, A. R., van Dyk, D., Arcache, M. J., Hodges, O., Lombard, C. J., Greenwood, J., & James, M. F. (2009). Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery. Anesthesiology. https://doi.org/10.1097/aln.0b013e3181b437e0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.