Impact of Pulse Oximetry Surveillance on Rescue Events and Intensive Care Unit Transfers: A Before-and-After Concurrence Study
Open accessAbstract
Background: Some preventable deaths in hospitalized patients are due to unrecognized deterioration. There are no publications of studies that have instituted routine patient monitoring postoperatively and analyzed impact on patient outcomes. Methods: The authors implemented a patient surveillance system based on pulse oximetry with nursing notification of violation of alarm limits via wireless pager. Data were collected for 11 months before and 10 months after implementation of the system. Concurrently, matching outcome data were collected on two other postoperative units. The primary outcomes were rescue events and transfers to the intensive care unit compared before and after monitoring change. Results: Rescue events decreased from 3.4 (1.89-4.85) to 1.2 (0.53-1.88) per 1,000 patient discharges and intensive care unit transfers from 5.6 (3.7-7.4) to 2.9 (1.4-4.3) per 1,000 patient days, whereas the comparison units had no change. Conclusions: Patient surveillance monitoring results in a reduced need for rescues and intensive care unit transfers.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The EHR contains a large amount of data that may be useful to identify patients at the highest risk of decompensation if the data are evaluated over time.
“The EHR contains a large amount of data that may be useful to identify patients at the highest risk of decompensation if the data are evaluated over time (37, 38).”
From Accessing Artificial Intelligence for Clinical Decision-Making (2021) · cites this paper as [37]
Six to eight hours may precede acute patient decompensation, which can provide ample time for interventions to be made.
“Six to eight hours may precede such acute patient decompensation, which can easily provide ample time for interventions to be made (37).”
From Accessing Artificial Intelligence for Clinical Decision-Making (2021) · cites this paper as [37]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 14 · Cited by 315
- Authors
- Taenzer, A. H., Pyke, J. B., McGrath, S. P., & Blike, G. T.
- Affiliations
- Assistant Professor of Anesthesiology and Pediatrics.
- Ph.D. Student.
- Dartmouth College (US)
- Dartmouth–Hitchcock Medical Center (US)
- Venue
- Anesthesiology
- Published
- 2010-02-01
- Volume
- 112
- Issue
- 2
- Pages
- 282-287
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2050002215
- Cited by
- 315
- References
- 14
- Citations by year
- 2026: 13 · 2025: 12 · 2024: 13 · 2023: 8 · 2022: 15 · 2021: 44 · 2020: 18 · 2019: 22 · 2018: 21 · 2017: 29 · 2016: 27 · 2015: 20 · 2014: 24 · 2013: 17 · 2012: 12
- FWCI
- 16.40
- Type
- journal article
- Language
- en
- Update notices
- erratum (2020-03-01)
- Open access
- bronze
- doi.org
- Locations
- Anesthesiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
- Keywords
- pulse oximetry, patient surveillance, postoperative monitoring, ICU transfer, preventable deaths, postoperative care
- MeSH terms
- Aged, Anesthesia, Emergency Medical Services, Female, Heart Arrest, Hemodynamics, Humans, Intensive Care Units, Male, Middle Aged, Monitoring, Physiologic, Oximetry, Postoperative Period, Transportation of Patients, Cohort Studies, Treatment Outcome, Orthopedic Procedures, Clinical Alarms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review