Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Variability in Blood and Blood Component Utilization as Assessed by an Anesthesia Information Management System

Frank, Steven M., Savage, Will J., Rothschild, Jim A., Rivers, Richard J., Ness, Paul M., Paul, Sharon L., Ulatowski, John A. · 2012 · Anesthesiology

Abstract

Background: Data can be collected for various purposes with anesthesia information management systems. The authors describe methods for using data acquired from an anesthesia information management system to assess intraoperative utilization of blood and blood components. Methods: Over an 18-month period, data were collected on 48,086 surgical patients at a tertiary care academic medical center. All data were acquired with an automated anesthesia recordkeeping system. Detailed reports were generated for blood and blood component utilization according to surgical service and surgical procedure, and for individual surgeons and anesthesiologists. Transfusion hemoglobin trigger and target concentrations were compared among surgical services and procedures, and between individual medical providers. Results: For all patients given erythrocytes, the mean transfusion hemoglobin trigger was 8.4 ± 1.5, and the target was 10.2 ± 1.5 g/dl. Variation was significant among surgical services (trigger range: 7.5 ± 1.2-9.5 ± 1.1, P = 0.0001; target range: 9.1 ± 1.2-11.3 ± 1.4 g/dl, P = 0.002), surgeons (trigger range: 7.2 ± 0.7-9.8 ± 1.0, P = 0.001; target range: 8.8 ± 0.9-11.8 ± 1.3 g/dl, P = 0.001), and anesthesiologists (trigger range: 7.2 ± 0.8-9.6 ± 1.2, P = 0.001; target range: 9.0 ± 0.9-11.7 ± 1.3 g/dl, P = 0.0004). The use of erythrocyte salvage, fresh frozen plasma, and platelets varied threefold to fourfold among individual surgeons compared with their peers performing the same surgical procedure. Conclusions: The use of data acquired from an anesthesia information management system allowed a detailed analysis of blood component utilization, which revealed significant variation among surgical services and surgical procedures, and among individual anesthesiologists and surgeons compared with their peers. Incorporating these methods of data acquisition and analysis into a blood management program could reduce unnecessary transfusions, an outcome that may increase patient safety and reduce costs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e318255e550

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 182

Metadata

Authors
Frank, S. M., Savage, W. J., Rothschild, J. A., Rivers, R. J., Ness, P. M., Paul, S. L., & Ulatowski, J. A.
Venue
Anesthesiology
Published
2012-07-01
Volume
117
Issue
1
Pages
99-106
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2155495795
Cited by
182
References
1
FWCI
14.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability in Blood and Blood Component Utilization as Assessed by an Anesthesia Information Management System. https://app.cochat.ai/papers/10.1097/aln.0b013e318255e550
The paper
Frank, S. M., Savage, W. J., Rothschild, J. A., Rivers, R. J., Ness, P. M., Paul, S. L., & Ulatowski, J. A. (2012). Variability in Blood and Blood Component Utilization as Assessed by an Anesthesia Information Management System. Anesthesiology. https://doi.org/10.1097/aln.0b013e318255e550

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.