The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Real-time Two-dimensional Ultrasound Guidance for Central Venous Cannulation: A Meta-analysis
Abstract
Background: Use of ultrasound-guided techniques to facilitate central venous cannulation (CVC) may reduce the risk of misplacement and complications. A meta-analysis was conducted to compare real-time two-dimensional ultrasound (RTUS) guidance technique with anatomical landmark technique for CVC to determine whether RTUS has any advantages. Methods: Randomized studies comparing outcomes in patients undergoing CVC with either RTUS or landmark technique were retrieved from PubMed, ISI Web of Knowledge, EMBASE, and OVID EBM Reviews from their inception to March 2012. Results: Twenty-six studies involving 4,185 CVC procedures met the inclusion criteria. Compared with landmark technique, patients with RTUS had a pooled relative risk (RR) of 0.18 (95% CI: 0.10–0.32) for cannulation failure, 0.25 (95% CI: 0.15–0.42) for arterial puncture, 0.30 (95% CI: 0.19–0.46) for hematoma, 0.21 (95% CI: 0.06–0.73) for pneumothorax, and 0.10 (95% CI: 0.02–0.54) for hemothorax from random-effects models. However, RTUS did not show a reduction in the risk of cannulation failure (RR = 0.26, 95% CI: 0.03–2.55), arterial puncture (RR = 0.34, 95% CI: 0.05–2.60), hematoma (RR = 0.13, 95% CI: 0.01–2.42), pneumothorax (RR = 0.40, 95% CI: 0.02–9.61), and hemothorax (RR = 0.40, 95% CI: 0.02–9.61) in children or infants when the limited data were analyzed. Conclusions: Among adults receiving CVC, RTUS was associated with decreased risks of cannulation failure, arterial puncture, hematoma, and hemothorax. Additional data of randomized studies are necessary to evaluate these outcomes in pediatric patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Assessing the Quality of Randomized Controlled Trials:Current Issues and Future Directions
Moher, D., Jadad, A. R., & Tugwell, P. (1996) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462300009570 · Cited by 436
Cited by
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011447 · Cited by 320
Franco‐Sadud, R., Schnobrich, D., Mathews, B. K., Candotti, C., Abdel‐Ghani, S., Perez, M. G., Rodgers, S. C., Mader, M. J., Haro, E. K., Dancel, R., et al. (2019) · Journal of Hospital Medicine · doi:10.12788/jhm.3287 · Cited by 260
Metadata
- Authors
- Wu, S.-Y., Ling, Q., Cao, L.-H., Wang, J., Xu, M.-X., & Zeng, W.-A.
- Venue
- Anesthesiology
- Published
- 2013-02
- Volume
- 118
- Issue
- 2
- Pages
- 361-375
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2020347824
- Cited by
- 213
- References
- 2
- FWCI
- 33.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time Two-dimensional Ultrasound Guidance for Central Venous Cannulation: A Meta-analysis. https://app.cochat.ai/papers/10.1097/aln.0b013e31827bd172
- The paper
- Wu, S.-Y., Ling, Q., Cao, L.-H., Wang, J., Xu, M.-X., & Zeng, W.-A. (2013). Real-time Two-dimensional Ultrasound Guidance for Central Venous Cannulation: A Meta-analysis. Anesthesiology. https://doi.org/10.1097/aln.0b013e31827bd172
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.